Issue 37, 2024

Fluorescence and colorimetric analysis of β-estradiol based on aptamer assembled spherical nucleic acids

Abstract

Detecting β-estradiol (E2) in environmental monitoring is a complex task due to its status as a significant environmental contaminant. The detection methods require precision, sensitivity, and the ability to be conducted on-site without expensive instrumentation. Herein, we developed a novel approach using E2 aptamer assembled spherical nucleic acids (SNAs), which combines the sensitivity of fluorescence and the simplicity of colorimetry. Initially, a fluorescein (FAM)-labeled DNA aptamer is attached to the surface of gold nanoparticles (AuNPs) through hybridization with thiol-labeled DNA, resulting in fluorescence quenching. However, when E2 is present, the aptamer specifically binds to it, displacing from the thiol-DNA and releasing from the AuNP's surface. This leads to the recovery of fluorescence, allowing for quantitative detection of E2 by measuring the increase in fluorescence signal. Additionally, E2 detection can also be achieved visually using ultraviolet light. For colorimetric analysis, we introduce another set of AuNPs modified with thiol-DNA complementary to the DNA remaining on the surface of the previous AuNPs. When E2 triggers the release of the aptamer, the DNA on both AuNPs hybridized to each other, causing the aggregation of AuNPs and resulting in a distinct color change from red to purple. The detection limits for fluorescence and colorimetric analyses are 1 nM and 5 nM, respectively. We successfully applied this biosensing strategy to determine E2 concentrations in tap water and serum samples. Furthermore, our assay exhibits high selectivity towards E2 over other estrogens. Overall, this innovative approach provides an effective and versatile method for convenient on-site monitoring of E2.

Graphical abstract: Fluorescence and colorimetric analysis of β-estradiol based on aptamer assembled spherical nucleic acids

Supplementary files

Article information

Article type
Paper
Submitted
08 Jul 2024
Accepted
25 Aug 2024
First published
26 Aug 2024
This article is Open Access
Creative Commons BY license

Anal. Methods, 2024,16, 6356-6363

Fluorescence and colorimetric analysis of β-estradiol based on aptamer assembled spherical nucleic acids

L. Chen, A. Yuan, D. Zhang, W. Xie and H. Peng, Anal. Methods, 2024, 16, 6356 DOI: 10.1039/D4AY01283F

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements