Post-collection purity correction for internal standard correction-high performance liquid chromatography-quantitative nuclear magnetic resonance

Abstract

Quantitative nuclear magnetic resonance (qNMR) has a potential risk of inaccurate quantification of complex organic compounds with low purity due to incomplete separation of the impurity signals and the target component signals. The high performance liquid chromatography-qNMR (HPLC-qNMR) method removes impurities from the sample by HPLC and accurately determines the purity of the sample by qNMR, avoiding the laborious, time-consuming, and costly step of qualitative and quantitative determination of impurities in conventional mass balance methods. An improved method, named post-collection purity correction for internal standard correction-HPLC-qNMR (ISC-HPLC-qNMR), was developed and demonstrated on a complex compound oxytetracycline with low purity. In this method, a correction factor was introduced to compensate for the inability to achieve 100% purity through the HPLC purification procedure. The purity value with standard deviation of the oxytetracycline study material using this method was 82.00% ± 0.82%, while that obtained from the conventional qNMR with deconvolution was 81.70% ± 0.35%. The consistency of these results demonstrated that the improved method extends the applicability to the samples where HPLC is not capable of purifying complex compounds with low purity to near 100%, especially containing highly similar structural-related impurities. Furthermore, this method allows purification and quantification without the need to identify impurities in the sample, resulting in significant savings of time and cost. Additionally, it effectively compensates for the limitations of qNMR deconvolution in handling peak overlap in the sample.

Graphical abstract: Post-collection purity correction for internal standard correction-high performance liquid chromatography-quantitative nuclear magnetic resonance

Supplementary files

Article information

Article type
Paper
Submitted
21 May 2024
Accepted
19 Jun 2024
First published
03 Jul 2024

Anal. Methods, 2024,16, 4775-4782

Post-collection purity correction for internal standard correction-high performance liquid chromatography-quantitative nuclear magnetic resonance

X. Li, W. Zhang, T. Huang, M. Li, F. Su, H. Wu and G. Tang, Anal. Methods, 2024, 16, 4775 DOI: 10.1039/D4AY00949E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements