Issue 2, 2024

Method validation for (ultra)-trace element concentrations in urine for small sample volumes in large epidemiological studies: application to the population-based epidemiological multi-ethnic study of atherosclerosis (MESA)

Abstract

Analysis of essential and non-essential trace elements in urine has emerged as a valuable tool for assessing occupational and environmental exposures, diagnosing nutritional status and guiding public health and health care intervention. Our study focused on the analysis of trace elements in urine samples from the Multi-Ethnic Study of Atherosclerosis (MESA), a precious resource for health research with limited sample volumes. Here we provide a comprehensive and sensitive method for the analysis of 18 elements using only 100 μL of urine. Method sensitivity, accuracy, and precision were assessed. The analysis by inductively coupled plasma mass spectrometry (ICP-MS) included the measurement of antimony (Sb), arsenic (As), barium (Ba), cadmium (Cd), cesium (Cs), cobalt (Co), copper (Cu), gadolinium (Gd), lead (Pb), manganese (Mn), molybdenum (Mo), nickel (Ni), selenium (Se), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), and zinc (Zn). Further, we reported urinary trace element concentrations by covariates including gender, ethnicity/race, smoking and location. The results showed good accuracy and sensitivity of the ICP-MS method with the limit of detections rangings between 0.001 μg L−1 for U to 6.2 μg L−1 for Zn. Intra-day precision for MESA urine analysis varied between 1.4% for Mo and 26% for Mn (average 6.4% for all elements). The average inter-day precision for most elements was <8.5% except for Gd (20%), U (16%) and Mn (19%) due to very low urinary concentrations. Urinary mean concentrations of non-essential elements followed the order of Sr > As > Cs > Ni > Ba > Pb > Cd > Gd > Tl > W > U. The order of urinary mean concentrations for essential trace elements was Zn > Se > Mo > Cu > Co > Mn. Non-adjusted mean concentration of non-essential trace elements in urine from MESA participants follow the order Sr > As > Cs > Ni > Ba > Pb > Cd > Gd > Tl > W > U. The unadjusted urinary mean concentrations of essential trace elements decrease from Zn > Se > Mo > Cu > Co > Mn.

Graphical abstract: Method validation for (ultra)-trace element concentrations in urine for small sample volumes in large epidemiological studies: application to the population-based epidemiological multi-ethnic study of atherosclerosis (MESA)

Supplementary files

Article information

Article type
Paper
Submitted
11 Sep 2023
Accepted
29 Nov 2023
First published
04 Dec 2023

Anal. Methods, 2024,16, 214-226

Method validation for (ultra)-trace element concentrations in urine for small sample volumes in large epidemiological studies: application to the population-based epidemiological multi-ethnic study of atherosclerosis (MESA)

K. Schilling, R. A. Glabonjat, O. Balac, M. Gálvez-Fernández, A. Domingo-Relloso, V. Slavkovich, J. Goldsmith, M. R. Jones, T. R. Sanchez and A. Navas-Acien, Anal. Methods, 2024, 16, 214 DOI: 10.1039/D3AY01605F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements