Issue 22, 2024

Nanozyme linked multi-array gas driven sensor for real-time quantitative detection of Group A streptococcus

Abstract

Group A streptococcus (GAS) is a pathogen typically transmitted through respiratory droplets and skin contact, causing an estimated 700 million mild non-invasive infections worldwide each year. There are approximately 650 000 infections that progress to severe invasive infections, even resulting in death. Therefore, the ability to detect GAS rapidly, accurately and in real time is important. Herein, we developed a nanozyme linked multi-array gas driven sensor (NLMAGS) to point-of-care testing of GAS within 2 h. The NLMAGS demonstrated excellent performance as it combined the advantages of nanozyme techniques, immunoassay techniques, and 3D printing techniques. Platinum- and palladium-rich nanozyme particles (Au@Pt@PdNPs) were synthesized and used to label monocloning antibodies as detection probes. Magnetic beads were labeled with monocloning antibodies as capture probes to establish a double-antibody sandwich immunoassay for the detection of GAS. The sandwich immune complex can catalyze the H2O2 substrate and produce O2. GAS quantification can be achieved by measuring the distance that the O2 pushes the ink drops forward in the sensor. Under optimized conditions, the NLMAGS quantitatively detected 24 spiked samples with a limit of detection (LOD) of 62 CFU mL−1, which was 5 times lower than that of ELISA (334 CFU mL−1). A strong correlation with the conventional ELISA was found (r = 0.99, P < 0.001). In comparison, the traditional lateral flow immunoassay based on Au@Pt@PdNPs-mAb2 (Au@Pt@PdNPs-LFIA) had a LOD of 104 CFU mL−1, which was significantly higher than that of NLMAGS. The NLMAGS demonstrated excellent sensitivity to GAS. The intra- and inter-assay precisions of the sensor were below 15%. Overall, the established NLMAGS has promising potential as a rapid and quantitative method for detecting GAS and can also be used to detect various pathogens.

Graphical abstract: Nanozyme linked multi-array gas driven sensor for real-time quantitative detection of Group A streptococcus

Supplementary files

Article information

Article type
Paper
Submitted
03 Jun 2024
Accepted
06 Oct 2024
First published
08 Oct 2024

Analyst, 2024,149, 5433-5442

Nanozyme linked multi-array gas driven sensor for real-time quantitative detection of Group A streptococcus

Q. Wang, P. Liu, K. Xiao, W. Zhou, J. Li and Y. Xi, Analyst, 2024, 149, 5433 DOI: 10.1039/D4AN00787E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements