Issue 12, 2024

External liquid calibration method for iodide chemical ionization mass spectrometry enables quantification of gas-phase per- and polyfluoroalkyl substances (PFAS) dynamics in indoor air

Abstract

Per- and polyfluoroalkyl substances (PFAS) are manufactured chemicals that have been detected across the globe. Fluorotelomer alcohols (FTOHs) are one PFAS class commonly found in indoor air due to emissions from consumer products (e.g., textiles and food packaging) and are human metabolic, atmospheric oxidative, and industrial precursors of perfluoroalkyl carboxylic acids (PFCAs). We developed a quantitative method for real-time analysis of gas-phase FTOHs, perfluoroalkyl acids (PFCAs and GenX), one perfluorooctane sulfonamide (EtFOSA), one fluorotelomer diol (FTdiOH), and one fluorinated ether (E2) using high-resolution time-of-flight chemical ionization mass spectrometry equipped with iodide reagent ion chemistry (I-HR-ToF-CIMS). Herein, we present a direct liquid injection method for external calibration, providing detection limits of 0.19–3.1 pptv for 3 s averaging and 0.02–0.44 pptv for 120 s averaging, with the exception of E2, which had detection limits of 1700 and 220 pptv for 3- and 120 s averaging, respectively. These calibrations enabled real-time gas-phase quantification of 6 : 2 FTOH in room air while microwaving popcorn, with an average peak air concentration of 31.6 ± 4.5 pptv measured 2 meters from a closed microwave. Additionally, 8 : 2 and 10 : 2 FTOH concentrations in indoor air were measured in the presence and absence of a rain jacket, with observed peak concentrations of 110 and 25 pptv, respectively. Our work demonstrates the ability of I-HR-ToF-CIMS to provide real-time air measurements of PFAS relevant to indoor human exposure settings and allow for PFAS source identification. We expect that real-time quantification of other gas-phase PFAS classes is possible, enabling advances in understanding PFAS sources, chemistry, and partitioning.

Graphical abstract: External liquid calibration method for iodide chemical ionization mass spectrometry enables quantification of gas-phase per- and polyfluoroalkyl substances (PFAS) dynamics in indoor air

Supplementary files

Article information

Article type
Paper
Submitted
19 Jan 2024
Accepted
29 Apr 2024
First published
30 Apr 2024

Analyst, 2024,149, 3405-3415

External liquid calibration method for iodide chemical ionization mass spectrometry enables quantification of gas-phase per- and polyfluoroalkyl substances (PFAS) dynamics in indoor air

M. J. Davern, G. V. West, C. M. A. Eichler, B. J. Turpin, Y. Zhang and J. D. Surratt, Analyst, 2024, 149, 3405 DOI: 10.1039/D4AN00100A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements