Issue 3, 2023

Experimental investigation of improved tolerance for concentration mismatch in potassium isotope analysis on a hexapole collision cell MC-ICP-MS (Nu Sapphire)

Abstract

Collision cell multi-collector inductively coupled plasma mass spectrometry (CC-MC-ICP-MS) has made routine high precision potassium (K) isotope analysis possible using sample-standard bracketing. However, as reported in previous studies, strict concentration match between a sample and bracketing standard (<2% tolerance reported from most labs worldwide) is often required to avoid analytical bias. This small tolerance for concentration mismatch would naturally lead to low analytical efficiency. To better characterize and potentially improve this, we conducted a series of experiments on the hexapole parameters of the Nu Sapphire CC-MC-ICP-MS. The results reveal that RF Ref. (the voltage of the RF alternating current applied to the hexapole rods) is the primary parameter that controls the concentration mismatch effect. For a set RF Bias Ref. value (the potential for the hexapole) of −0.8 V, the optimal RF Ref. value of 1.05 V identified by the flattest part in the 41K/39K ratio versus RF Ref. plot has increased the tolerance for K concentration mismatch to 30% from 4% at a RF Ref. of 1.5 V. The cell gas flow rate is another important parameter and optimal values of 2 sccm and 5 sccm are recommended for He and H2, respectively. A much higher tolerance for concentration mismatch using optimized parameters has greatly improved the efficiency of high precision K isotope analyses using CC-MC-ICP-MS and will open the possibility for in situ K isotopic measurements.

Graphical abstract: Experimental investigation of improved tolerance for concentration mismatch in potassium isotope analysis on a hexapole collision cell MC-ICP-MS (Nu Sapphire)

Supplementary files

Article information

Article type
Technical Note
Submitted
17 Jan 2023
Accepted
20 Jan 2023
First published
23 Jan 2023

J. Anal. At. Spectrom., 2023,38, 603-608

Experimental investigation of improved tolerance for concentration mismatch in potassium isotope analysis on a hexapole collision cell MC-ICP-MS (Nu Sapphire)

W. Li, Y. Zhao, B. Su, B. Gao, J. Wang and S. Liu, J. Anal. At. Spectrom., 2023, 38, 603 DOI: 10.1039/D3JA00022B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements