Issue 8, 2023

Ecofriendly LC-MS/MS and TLC-densitometric methods for simultaneous quantitative assay and monitoring of BEGEV regimen, in vivo pharmacokinetic study application

Abstract

To date no analytical method has been developed for the determination of the BEGEV regimen and no study has investigated the kinetic interaction between the drugs, to give us priorities for further clinical study, so two rapid, accurate, sensitive and ecofriendly chromatographic methods were developed for the simultaneous determination of bendamustine (BEN), gemcitabine (GEM) and vinorelbine (VIB) using sildenafil (SIL) as an internal standard (IS) for the purpose of an in vivo pharmacokinetics study in rats. Firstly, the LC-MS/MS method was performed using a mixture of methanol and a 0.1% aqueous solution of formic acid as the mobile phase on a ZORBAX Eclipse Plus C18 (4.6 mm × 150 mm, 5 μm) column as the stationary phase. BEN, GEM and VIB were ionized by positive ions and detected in the multi-reaction monitoring (MRM) mode using precursor → products of m/z 358.20 → 228.25 for BEN, m/z 264.05 → 112.15 for GEM, m/z 779.55 → 122.20 for VIB and m/z 475.00 → 58.35 for SIL. Secondly, TLC-densitometry was applied on TLC silica gel plates using methanol : ethyl acetate (8 : 2, v/v) as the developing system when the separated peaks were scanned at 280 nm. FDA guidelines were followed for validation of the proposed methods, which presented acceptable ranges; then they were applied for an in vivo study in rats with a quantitative determination of each drug after single or combined administration for an investigation of any suspected drug–drug interaction, and all pharmacokinetic parameters were calculated for therapeutic drug monitoring of those drugs. Green analytical chemistry principles were considered during all the procedural steps to ensure the greenness and the safety of the methods, which were evaluated using four assessment tools, eco-scale assessment, the national environmental method index (NEMI), the green analytical procedure index (GAPI) and the analytical greenness metric approach (AGREE), and the results were satisfactory.

Graphical abstract: Ecofriendly LC-MS/MS and TLC-densitometric methods for simultaneous quantitative assay and monitoring of BEGEV regimen, in vivo pharmacokinetic study application

Supplementary files

Article information

Article type
Paper
Submitted
16 Jan 2023
Accepted
25 Jan 2023
First published
02 Feb 2023

Anal. Methods, 2023,15, 1016-1027

Ecofriendly LC-MS/MS and TLC-densitometric methods for simultaneous quantitative assay and monitoring of BEGEV regimen, in vivo pharmacokinetic study application

M. M. Z. Sharkawi, N. R. Mohamed, M. T. El-Saadi and N. H. Amin, Anal. Methods, 2023, 15, 1016 DOI: 10.1039/D3AY00081H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements