Issue 19, 2023

A microfluidic-chip-based system with loop-mediated isothermal amplification for rapid and parallel detection of Trichomonas vaginalis and human papillomavirus

Abstract

Cervical cancer is a significant global health issue primarily caused by high-risk types of human papillomavirus (HPV). Recent studies have reported an association between Trichomonas vaginalis (T. vaginalis) infections and HPV infections, highlighting the importance of simultaneously detecting these pathogens for effective cervical cancer risk management. However, current methods for detecting both T. vaginalis and HPV are limited. In this study, we present a novel approach using a microfluidic-chip-based system with loop-mediated isothermal amplification (LAMP) for the rapid and parallel detection of T. vaginalis, HPV16, HPV18, and HPV52 in a reagent-efficient and user-friendly manner. Compared to conventional LAMP assays in tubes, our system exhibits enhanced sensitivity with values of 2.43 × 101, 3.00 × 102, 3.57 × 101, and 3.60 × 102 copies per reaction for T. vaginalis, HPV16, HPV18, and HPV52, respectively. Additionally, we validated the performance of our chip by testing 47 clinical samples, yielding results consistent with the diagnostic methods used by the hospital. Therefore, our system not only offers a promising solution for concurrent diagnosis of T. vaginalis and HPV infections, particularly in resource-limited areas, due to its cost-effectiveness, ease of use, and rapid and accurate detection performance, but can also contribute to future research on the co-infection of these two pathogens. Moreover, the system possesses the capability to simultaneously detect up to 22 different types of pathogens, making it applicable across a wide range of domains such as diagnostics, food safety, and water monitoring.

Graphical abstract: A microfluidic-chip-based system with loop-mediated isothermal amplification for rapid and parallel detection of Trichomonas vaginalis and human papillomavirus

Supplementary files

Article information

Article type
Paper
Submitted
04 Jul 2023
Accepted
15 Aug 2023
First published
18 Aug 2023

Analyst, 2023,148, 4820-4828

A microfluidic-chip-based system with loop-mediated isothermal amplification for rapid and parallel detection of Trichomonas vaginalis and human papillomavirus

Z. Mao, A. Deng, X. Jin, M. Li, W. Lv, L. Huang, H. Zhong, H. Yang, S. Wang, Y. Shi, L. Zhang, Q. Liao and G. Huang, Analyst, 2023, 148, 4820 DOI: 10.1039/D3AN01123B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements