Issue 17, 2023

Fabrication of a paper-based facile and low-cost microfluidic device and digital imaging technique for point-of-need monitoring of hypochlorite

Abstract

Lab-on-a-paper-based devices are promising alternatives to the existing arduous techniques for point-of-need monitoring. The present work reports an instant and facile method to produce a microfluidic paper-based analytical device (μPAD). The fabricated μPAD has been used to detect hypochlorite (OCl) by incorporating newly synthesized chromo-fluorogenic ratiometric probes 1 and 2 into the sample reception zone. The probes showed high selectivity and fast response (<10 s) toward OCl with an excellent linear relationship in the concentration range of 0–100 μM. The concentration-dependent fluorometric change driven by the reaction of 1@μPAD with OCl has been monitored using gel-doc imaging systems, which is unprecedented. Digitizing the intensity of the colour solution with different mathematical models of colour has developed a straightforward method for monitoring OCl without any interference from its competitors. 1@μPAD can detect OCl at ∼10 times lower than the WHO recommended limit. The detection limit of 1@μPAD via a digital camera-based fluorescence technique was found to be better over digital camera-based cuvette assays. Therefore, 1@μPAD has been successfully utilized to monitor OCl in actual environmental water samples with portability, ease of use, and sensitivity. The analytical RSD was found to be ≤3% based on fluorimetric detection using 1@μPAD. The chemodosimetric reaction between OCl and the probe was evidenced by UV-vis and fluorescence spectroscopy, 1H NMR, and ESI-MS. The rapid response time, biocompatibility, low cytotoxicity, 100% aqueous solubility, ratiometric feature, and exclusive OCl selectivity over other competitive ROS/RNS successfully lead to the application of the probes for bioimaging of exogenous as well as endogenous OCl in normal cells (HEK293) and cancerous cells (HeLa).

Graphical abstract: Fabrication of a paper-based facile and low-cost microfluidic device and digital imaging technique for point-of-need monitoring of hypochlorite

Supplementary files

Article information

Article type
Paper
Submitted
05 Apr 2023
Accepted
12 Jul 2023
First published
24 Jul 2023

Analyst, 2023,148, 4072-4083

Fabrication of a paper-based facile and low-cost microfluidic device and digital imaging technique for point-of-need monitoring of hypochlorite

S. Debnath, R. Ghosh, Pragti, S. Mukhopadhyay, K. V. Baskaran and P. B. Chatterjee, Analyst, 2023, 148, 4072 DOI: 10.1039/D3AN00533J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements