Issue 7, 2022

Comparison of GC-ICP-MS, GC-EI-MS and GC-EI-MS/MS for the determination of methylmercury, ethylmercury and inorganic mercury in biological samples by triple spike species-specific isotope dilution mass spectrometry

Abstract

We present here the determination of Hg species in complicated matrices by three different mass spectrometric techniques coupled to gas chromatography to evaluate if ionization suppression or spectral interferences are limiting factors to provide accurate and precise determinations, particularly when using the electron ionization source. GC-ICP-MS, GC-EI-MS and GC-EI-MS/MS are compared for the determination of Hg(II), methylmercury and ethylmercury by triple spiking isotope dilution mass spectrometry in the certified matrix reference materials DOLT-4 (dogfish liver), IAEA-085 (human hair), IAEA-086 (human hair) and SRM-955c (caprine blood). The analytical figures of merit such as accuracy and precision and detection limits were compared. Overall, GC-ICP-MS has demonstrated its superiority in terms of accuracy, precision, detection limits and matrix tolerance while GC-EI-MS provided results in agreement with the certified values for hair and dogfish liver reference materials. GC-ICP-MS provided three times lower detection limits for Hg(II) and MeHg than GC-EI-MS and between 4 to 10 times lower than GC-EI-MS/MS. The analysis of more complicated matrices at lower concentration levels, such as caprine blood, has shown important limitations of molecular MS to provide accurate and precise determinations. The higher selectivity offered by GC-EI-MS/MS in the selective reaction monitoring mode does not result in improved analytical characteristics due to lower yield in the formation of in-cell product ions for propylated Hg species.

Graphical abstract: Comparison of GC-ICP-MS, GC-EI-MS and GC-EI-MS/MS for the determination of methylmercury, ethylmercury and inorganic mercury in biological samples by triple spike species-specific isotope dilution mass spectrometry

Supplementary files

Article information

Article type
Technical Note
Submitted
14 Mar 2022
Accepted
26 May 2022
First published
27 May 2022

J. Anal. At. Spectrom., 2022,37, 1462-1470

Comparison of GC-ICP-MS, GC-EI-MS and GC-EI-MS/MS for the determination of methylmercury, ethylmercury and inorganic mercury in biological samples by triple spike species-specific isotope dilution mass spectrometry

L. Suárez-Criado, S. Queipo-Abad, A. Rodríguez-Cea, P. Rodríguez-González and J. I. García Alonso, J. Anal. At. Spectrom., 2022, 37, 1462 DOI: 10.1039/D2JA00086E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.