Issue 5, 2022

Quantitative analysis of mercury in liquid samples using laser-induced breakdown spectroscopy combined with shear thickening fluid

Abstract

Laser-induced breakdown spectroscopy (LIBS) has been widely used to analyze heavy metals in the environment. When LIBS is used to analyze mercury (Hg) in liquids, water splashing, surface ripples, and plasma quenching will reduce analytical sensitivity and accuracy. In this work, a new method that combines shear thickening fluid with LIBS (STF-LIBS) was first proposed to improve the analytical capability of Hg in liquids. In this method, liquid samples were prepared as shear thickening fluid (STF) samples for LIBS detection. The sample preparation takes 30 seconds and needs 1.5 ml of liquid sample. The time evolution of laser-induced plasma plumes and Hg atom line emission intensities of the STF sample were analyzed. The calibration curves of Hg(I)253.65 nm were constructed under the optimized parameters. The results showed that, the evolution time of plasma plumes in the STF sample was 1.57 times longer than that in the liquid drop sample. The emission intensity of Hg(I) 253.65 nm in the STF sample was 3.96 times higher than that in the liquid drop sample under the optimized parameters. According to the calibration curves, the limit of detection (LoD) and coefficient of determination (R2) of STF-LIBS were 0.771 mg L−1 and 0.982, respectively. Compared with direct analysis of liquid drop samples, STF-LIBS improved both the analytical sensitivity and the analytical accuracy of Hg in liquid samples, with the LoD improved by 53.24 times and R2 increased by 0.148. The practicability of STF-LIBS was verified by analysis of Hg in rivers and domestic wastewater, and the recovery values were in the range of 91.6–104.9%.

Graphical abstract: Quantitative analysis of mercury in liquid samples using laser-induced breakdown spectroscopy combined with shear thickening fluid

Article information

Article type
Paper
Submitted
14 Dec 2021
Accepted
14 Mar 2022
First published
15 Mar 2022

J. Anal. At. Spectrom., 2022,37, 1023-1031

Quantitative analysis of mercury in liquid samples using laser-induced breakdown spectroscopy combined with shear thickening fluid

Y. Wang, Y. Bu, Y. Cai and X. Wang, J. Anal. At. Spectrom., 2022, 37, 1023 DOI: 10.1039/D1JA00431J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements