Issue 41, 2021

Blood rheometer based on microflow manipulation of continuous blood flows using push-and-back mechanism

Abstract

To understand the contributions of rheological properties to microcirculation, the simultaneous measurement of multiple rheological properties under continuous blood flows has been emphasized. However, existing methods exhibit limitations in terms of continuous and simultaneous monitoring. In this study, a simple method is suggested for simultaneously measuring four rheological properties (i.e., red blood cell (RBC) aggregation, blood viscosity, blood junction pressure, and RBC sedimentation) under a continuous blood flow. Using the push-and-back mechanism, which comprises a co-flowing channel, a test chamber, and an air compliance unit (ACU), blood is supplied to the test chamber and restored into the co-flowing channel periodically and reversely. First, RBC aggregation is quantified based on the intensity of the blood image in the test chamber. Second, blood viscosity and blood junction pressure are determined by analyzing the interface in the co-flowing channel. Lastly, RBC sedimentation is evaluated by analyzing the intensity of the blood image in the blood chamber. Based on quantitative studies involving several vital factors, the tubing length of ACU is set to L = 30 mm. The reference fluid (glycerin [20%]) is controlled in a periodic on–off manner (period = 240 s, and flow rate = 1 mL h−1). The blood flow rate is maintained at 1 mL h−1. Subsequently, the present method is used to determine the rheological properties of several blood samples with different hematocrits or diluents. Compared with previous studies, the present method yields sufficiently consistent trends with respect to the hematocrit level or concentration of dextran solution. The experimental results imply that the present method enables simultaneous and consistent measurements of four rheological properties of blood under continuous blood flows. This method can be regarded as a promising method for monitoring multiple rheological properties of blood circulating under an in vitro closed fluidic circuit.

Graphical abstract: Blood rheometer based on microflow manipulation of continuous blood flows using push-and-back mechanism

Supplementary files

Article information

Article type
Paper
Submitted
04 Jun 2021
Accepted
24 Sep 2021
First published
24 Sep 2021

Anal. Methods, 2021,13, 4871-4883

Blood rheometer based on microflow manipulation of continuous blood flows using push-and-back mechanism

Y. J. Kang, Anal. Methods, 2021, 13, 4871 DOI: 10.1039/D1AY00948F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements