Issue 34, 2020

Comparing glucose and urea enzymatic electrochemical and optical biosensors based on polyaniline thin films

Abstract

Analytical sensors that can detect chemical (including biological) analytes are becoming increasingly widespread within the field of analytical chemistry. More than this, in a world tending towards the ‘internet-of-things’, the miniaturization of such devices is becoming increasingly urgent. Accordingly, electrochemical methods that are simultaneously multiplexable and effective at a miniature scale are receiving much attention. In the present work, we compare the label-free electrochemical response of enzymatic biosensors with the response of their optical counterpart. As a proof-of-concept we compare the electrochemical impedimetric response and the first time described capacitive response of enzymatic biosensors to their optical reflectance response (measured in the visible region using a portable handset spectrophotometer). The target was the detection of glucose and urea. The chemical platform of the sensors was composed of enzymatically functionalized polyaniline thin films. Sensitivity, linearity, and the limit of detection were analyzed for both electrochemical and optical instrumental settings. We found that the impedimetric/capacitive electrochemical setup produced a response that was of a similar quality to the optical response (sensitivities of 10.7 ± 0.7, 7.4 ± 0.7 and 4.3 ± 0.2% per decade for impedimetric, capacitive and optical glucose biosensors, respectively) with a broader linear range (10−4 to 10−1 mol L−1 for both glucose and urea biosensors) and similar limit-of-detection in the range of 1 μmol L−1 within a relevant and practical diagnosis range for biomedical applications.

Graphical abstract: Comparing glucose and urea enzymatic electrochemical and optical biosensors based on polyaniline thin films

Article information

Article type
Paper
Submitted
20 May 2020
Accepted
23 Jul 2020
First published
23 Jul 2020

Anal. Methods, 2020,12, 4199-4210

Comparing glucose and urea enzymatic electrochemical and optical biosensors based on polyaniline thin films

H. J. Nogueira Pedroza Dias Mello, P. R. Bueno and M. Mulato, Anal. Methods, 2020, 12, 4199 DOI: 10.1039/D0AY01018A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements