Issue 8, 2019

A smartphone fluorescence imaging-based mobile biosensing system integrated with a passive fluidic control cartridge for minimal user intervention and high accuracy

Abstract

A key challenge for realizing mobile device-based on-the-spot environmental biodetection is that a biosensor integrated with a fluid handling sensor cartridge must have acceptable accuracy comparable to that of conventional standard analytical methods. Furthermore, the user interface must be easy to operate, technologically plausible, and concise. Herein, we introduced an advanced smartphone imaging-based fluorescence microscope designed for Hg2+ monitoring by utilizing a biosensor cartridge that reduced user intervention via time-sequenced passive fluid handling. The cartridge also employed a metal-nanostructured plastic substrate for complementing the fluorescence signal output; this helped the realization of high-accuracy detection, in which a ratiometric dual-wavelength detection method was applied. Using 30 samples of Hg2+-spiked wastewater, we showed that our device, which has a detection limit of ∼1 pM, can perform analytical assays accurately. The detection results from our method were in good linearity and agreement with those of conventional standard methods. We conclude that the integration of a simple-to-use biosensor cartridge, fluorescence signal-enhancing substrate, dual-wavelength detection, and quantitative image data processing on a smartphone has great potential to make any population accessible to small-molecule detection, which has been performed in centralized laboratories for environmental monitoring.

Graphical abstract: A smartphone fluorescence imaging-based mobile biosensing system integrated with a passive fluidic control cartridge for minimal user intervention and high accuracy

Supplementary files

Article information

Article type
Paper
Submitted
10 Dec 2018
Accepted
11 Mar 2019
First published
12 Mar 2019

Lab Chip, 2019,19, 1502-1511

A smartphone fluorescence imaging-based mobile biosensing system integrated with a passive fluidic control cartridge for minimal user intervention and high accuracy

W. Lee, Y. Park, J. Park, S. Shrivastava, Y. Son, H. Choi, J. Lee, B. Jeon, H. Lee and N. Lee, Lab Chip, 2019, 19, 1502 DOI: 10.1039/C8LC01344F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements