Issue 15, 2019

Design and fabrication of surface capped palladium nanoclusters for the subnanomolar sensing of glutathione

Abstract

In this work, a palladium atomic cluster modified glassy carbon electrode (PdAC/GCE) was developed by potentiodynamic electrodeposition in the presence of an anionic surfactant for the electrochemical detection of glutathione (GSH). The morphology and structure of the prepared clusters were characterized by dynamic light scattering, matrix-assisted laser desorption ionization time of flight mass spectrometry, high-resolution transmission electron microscopy and spectroscopic methods. The modified electrode detects subnanomolar levels of glutathione, by monitoring the reduction peak of the Pd(0)/Pd(II) redox couple at the interface of Pd clusters deposited on a glassy carbon electrode in phosphate buffer using the differential pulse cathodic stripping voltammetry (DPCSV) technique. Under optimum conditions, the modified electrode shows a strong electrocatalytic response for GSH with high selectivity and sensitivity, a fast response, a wide linear range, a low detection limit (32 pM), excellent reproducibility with a limit of quantification of 1.6 × 10−10 M and a good precision of 0.38% for 1 × 10−8 M glutathione. Thus, it shows moderately good reproducibility and has reasonable selectivity towards some of the other important amino acids and biologically relevant molecules. To gain a better understanding of such an excellent sensor performance achieved with this electrode, studies were undertaken to pinpoint the electrode kinetics of charge transfer processes. The developed sensor was demonstrated for the quantification of glutathione in human serum samples with satisfactory accuracy. These features indicate that the prepared Pd cluster modified GCE with a unique electronic structure offers an excellent biosensing platform for sensitive and selective detection of glutathione.

Graphical abstract: Design and fabrication of surface capped palladium nanoclusters for the subnanomolar sensing of glutathione

Supplementary files

Article information

Article type
Paper
Submitted
06 Dec 2018
Accepted
13 Mar 2019
First published
01 Apr 2019

Anal. Methods, 2019,11, 2089-2096

Design and fabrication of surface capped palladium nanoclusters for the subnanomolar sensing of glutathione

P. K. Aneesh, C. Govind and S. R. Nambiar, Anal. Methods, 2019, 11, 2089 DOI: 10.1039/C8AY02670J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements