Issue 6, 2019

Study of chromatographic fractions from carbon dots isolated by column chromatography and a binary gradient elution via RP-HPLC

Abstract

Carbon dots (C-dots) have abundant functional groups on their surface, which affect their luminescence properties, detection and structure. Therefore, it is necessary to purify the synthesized C-dots by certain preparative chromatography, e.g. silica gel column chromatography and reversed phase high performance liquid chromatography (RP-HPLC). RP-HPLC coupled with UV absorbance detection has been applied for studying the chromatographic behavior of C-dots which can be prepared by one-step calcination of the precursors citric acid and urea. Herein, we study in detail the effects of gradient elution conditions and the appropriate flow rate of the mobile phase on the RP-HPLC of C-dots. We investigated the performance of different proportions of precursors and found the best proportion of citric acid and urea for obtaining C-dots. By using silica gel column chromatography, we get the best fraction which did not have a bathochromic shift (510–540 nm) when excited by 340–460 nm, while other fractions have a bathochromic shift (420–530 nm) when excited by 340–460 nm. Our results indicate that C-dot fractions with a better fluorescence performance and size distribution can be obtained via purification. The C-dot fractions emitted stable orange and yellow luminescence colors under a single-wavelength UV light. It is anticipated that our silica gel column chromatography and RP-HPLC methodology will open a new avenue to obtain excitation-independent C-dots.

Graphical abstract: Study of chromatographic fractions from carbon dots isolated by column chromatography and a binary gradient elution via RP-HPLC

Supplementary files

Article information

Article type
Paper
Submitted
05 Dec 2018
Accepted
19 Dec 2018
First published
19 Dec 2018

Anal. Methods, 2019,11, 760-766

Study of chromatographic fractions from carbon dots isolated by column chromatography and a binary gradient elution via RP-HPLC

L. Liu and Z. Xu, Anal. Methods, 2019, 11, 760 DOI: 10.1039/C8AY02660B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements