Issue 8, 2019

Standalone interferometry-based calibration of convex lens-induced confinement microscopy with nanoscale accuracy

Abstract

Strongly confined environments (confined dimensions between 1–100 nm) represent unique challenges and opportunities for understanding and manipulating molecular behavior due to the significant effects of electric double layers, high surface-area to volume ratios, and other phenomena at the nanoscale. Convex Lens-induced Confinement (CLiC) can be used to analyze the dynamics of individual molecules or particles confined in a planar slit geometry with continuously varying gap thickness. We describe an interferometry-based method for precise measurement of the slit pore geometry. Specifically, this approach permitted accurate characterization of separation distances as small as 5 nm, with 1 nm precision, without a priori knowledge or assumptions about the contact geometry, as well as a greatly simplified experimental setup that required only a lens, coverslip, and inverted microscope. The interferometry-based measurement of gap height offered a distinct advantage over conventional fluorescent dye-based methods; e.g., accurate interferometric height measurements were made at low gap heights regardless of solution conditions, while the concentration of fluorescent dye was significantly impacted by solution conditions such as ionic strength or pH. The accuracy of the interferometric measurements was demonstrated by comparing the experimentally measured concentration of a charged fluorescent dye as a function of gap thickness with dye concentration profiles calculated using Debye–Hückel theory. Accurate characterization of nanoscale gap thickness will enable researchers to study a variety of practical and biologically relevant systems within the CLiC geometry.

Graphical abstract: Standalone interferometry-based calibration of convex lens-induced confinement microscopy with nanoscale accuracy

Supplementary files

Article information

Article type
Paper
Submitted
26 Nov 2018
Accepted
27 Feb 2019
First published
28 Feb 2019

Analyst, 2019,144, 2628-2634

Author version available

Standalone interferometry-based calibration of convex lens-induced confinement microscopy with nanoscale accuracy

G. T. Morrin, D. F. Kienle and D. K. Schwartz, Analyst, 2019, 144, 2628 DOI: 10.1039/C8AN02300J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements