Petroleomics via Orbitrap mass spectrometry with resolving power above 1 000 000 at m/z 200

Author affiliations

Abstract

The performance of the high-field MegaOrbitrap Fourier transform mass spectrometer (FT-MS) with electrospray ionization (ESI) was evaluated to perform petroleum sample characterization via classical petroleomics approaches. Pertinent parameters that underpin the main figures of merit, that is, signal to noise ratios, dynamic range, spectral error, scan speed, mass accuracy and mass resolving power = Rp, and provide subsidies to develop these analyzers were tested. Comparisons are made with data obtained using the most common petroleomics instrument, which is a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS), that has been used in the last decade in our laboratory for crude oil analysis providing Rp of 340 000 at m/z 400 with transients of 3 s duration, and has been extensively demonstrated to fulfill all major requirements for precise petroleomics investigations. The high-field compact MegaOrbitrap mass analyzer, when operated at an Rp = 840 000 at m/z 400 (Rp > 1 000 000 at m/z 200) with a detection time of 3 s, was found to be well suited for adequate characterization of crude oil. Accurate class classification and mass accuracy below 1 ppm was obtained leading to proper, comprehensive petroleomics characterization.

Graphical abstract: Petroleomics via Orbitrap mass spectrometry with resolving power above 1 000 000 at m/z 200

Back to tab navigation

Supplementary files

Publication details

The article was received on 16 Nov 2017, accepted on 27 Jan 2018 and first published on 07 Feb 2018


Article type: Paper
DOI: 10.1039/C7RA12509G
Citation: RSC Adv., 2018,8, 6183-6191
  • Open access: Creative Commons BY license
  •   Request permissions

    Petroleomics via Orbitrap mass spectrometry with resolving power above 1 000 000 at m/z 200

    E. M. Schmidt, M. A. Pudenzi, J. M. Santos, C. F. F. Angolini, R. C. L. Pereira, Y. S. Rocha, E. Denisov, E. Damoc, A. Makarov and M. N. Eberlin, RSC Adv., 2018, 8, 6183
    DOI: 10.1039/C7RA12509G

    This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. Material from this article can be used in other publications provided that the correct acknowledgement is given with the reproduced material.

    Reproduced material should be attributed as follows:

    • For reproduction of material from NJC:
      [Original citation] - Published by The Royal Society of Chemistry (RSC) on behalf of the Centre National de la Recherche Scientifique (CNRS) and the RSC.
    • For reproduction of material from PCCP:
      [Original citation] - Published by the PCCP Owner Societies.
    • For reproduction of material from PPS:
      [Original citation] - Published by The Royal Society of Chemistry (RSC) on behalf of the European Society for Photobiology, the European Photochemistry Association, and RSC.
    • For reproduction of material from all other RSC journals:
      [Original citation] - Published by The Royal Society of Chemistry.

    Information about reproducing material from RSC articles with different licences is available on our Permission Requests page.

Search articles by author

Spotlight

Advertisements