Jump to main content
Jump to site search

Issue 20, 2018
Previous Article Next Article

Detection of Escherichia coli bacteria by impact electrochemistry

Author affiliations

Abstract

We report the redox mediated detection of Escherichia coli bacteria at carbon microelectrodes, using the impact electrochemistry technique. By employing N,N,N′,N′-tetramethyl-para-phenylene-diamine (TMPD) as redox mediator a concentration dependency for bacteria impacts was observed, whereby its impact frequency is shown to be in good agreement with theoretically predicted values.

Graphical abstract: Detection of Escherichia coli bacteria by impact electrochemistry

Back to tab navigation

Supplementary files

Publication details

The article was received on 30 Aug 2018, accepted on 17 Sep 2018 and first published on 17 Sep 2018


Article type: Communication
DOI: 10.1039/C8AN01675E
Citation: Analyst, 2018,143, 4840-4843
  •   Request permissions

    Detection of Escherichia coli bacteria by impact electrochemistry

    R. A. S. Couto, L. Chen, S. Kuss and R. G. Compton, Analyst, 2018, 143, 4840