A background-subtraction strategy leads to ratiometric sensing of oxygen without recalibration

Abstract

Luminescence-quenching based optical oxygen sensors have wide applications in many fields, which have already replaced almost 40% of the commercial market share dominated previously by the Clark oxygen electrode. The majority of optical oxygen sensors are based on lifetime measurement, which are precise, but are relatively expensive, and require high-speed electronics and detecting circuits. Alternatively, oxygen concentration can be measured via a luminescence intensity change, which is a referenced approach according to the Stern–Volmer equation. However, luminescence intensity based measurement tends to be highly influenced by background light. At a given sensor composition, different instrumentation setups, sensor surface roughnesses and thicknesses, and environmental light will result in significantly different calibration curves and sensitivities. This makes luminescence-intensity based optical sensors almost impossible to use practically, because each sensor needs to be recalibrated before use, and the calibration curve each time is quite different. We have solved this problem by introducing a new background-subtraction strategy. After background subtraction, oxygen sensors with different probe concentrations, instrumentation setups, surface roughnesses, supporting matrixes, and at different temperatures present identical calibration curves. This could greatly reduce the calibration task during practical use. Combined with the advantages of low price and a simple optical configuration, the new method will significantly promote wider applications of optical oxygen sensors.

Graphical abstract: A background-subtraction strategy leads to ratiometric sensing of oxygen without recalibration

Supplementary files

Article information

Article type
Paper
Submitted
25 May 2018
Accepted
31 Aug 2018
First published
03 Sep 2018

Analyst, 2018,143, 5120-5126

A background-subtraction strategy leads to ratiometric sensing of oxygen without recalibration

Y. Zhang, L. Ding, W. Zhang, X. Zhang, Y. Lian and X. Wang, Analyst, 2018, 143, 5120 DOI: 10.1039/C8AN00967H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements