Issue 20, 2016

NIR spectrophotometry with integrated beam splitter as a process analytical technology for meat composition analysis

Abstract

This study aims at evaluating the potential of a multipoint NIR spectrophotometer system based on a Fabry–Perot interferometer, which incorporates a beam splitter, combined with a four point photodiode array detector and collimated light for performing on-line analysis of beef composition. Additionally it also aims at analysing the spectral information obtained with the baseline correction setting and compares it to the information obtained using a conventional approach. The system was employed to spatially predict the composition of fat trimmings of mixed minced beef samples at varied path lengths (1, 1.5 and 4 cm). The system's performance was tested in two optional modes; (a) without baseline correction adjustment and (b) with baseline correction adjustment. Both measuring modes of the spectrophotometer demonstrated individual advantages in particular situations; the first situation evaluated the simultaneous analysis of different samples set at different path lengths per probe, whereas a second situation focused on sudden changes of path lengths of the same sample per probe during a single analysis. Partial least squares regression (PLSR) was employed to establish the quantitative relationship between the spectral data and its proximate analysis values. Overall results showed good predictions for all the chemical attributes. It was concluded from the results that a baseline correction adjustment setting is needed when sudden changes in the effective path length occur, while in a case where similar path lengths are encountered, both modes could be used, obtaining good and similar performances.

Graphical abstract: NIR spectrophotometry with integrated beam splitter as a process analytical technology for meat composition analysis

Supplementary files

Article information

Article type
Paper
Submitted
20 Mar 2016
Accepted
05 May 2016
First published
05 May 2016

Anal. Methods, 2016,8, 4134-4141

NIR spectrophotometry with integrated beam splitter as a process analytical technology for meat composition analysis

Y. Dixit, M. P. Casado-Gavalda, R. Cama-Moncunill, M. Markiewicz-Keszycka, P. Cruise, F. Jacoby, P. J. Cullen and C. Sullivan, Anal. Methods, 2016, 8, 4134 DOI: 10.1039/C6AY00816J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements