Issue 113, 2015

In situ nano-fibrillation of microinjection molded poly(lactic acid)/poly(ε-caprolactone) blends and comparison with conventional injection molding

Abstract

In this paper, the microinjection molding (μIM) of poly(lactic acid) (PLA)/poly(ε-caprolactone) (PCL) blend as well as a full comparison with the conventional injection molding (CIM) was carried out. The prepared PLA/PCL blend micropart and macropart were characterized by using various measurements. The results showed that μIM and CIM have a significantly different influence on the structure and performance of the PLA/PCL blend. μIM leads to a remarkable reduction in the domain size of PCL dispersed phase to the nanometer range, improvement in interfacial compatibility and narrower domain size distribution. Very interestingly, there are PCL nano fibrils in situ formed and oriented along the melt flow direction in the μIM micropart, i.e. the occurrence of an in situ PCL nano-fibrillation phenomenon. Comparatively, only PCL micro fibrils are formed in the CIM macropart, i.e. the occurrence of PCL micro-fibrillation. For both micropart and macropart, the shear layer shows much higher degrees of PCL nano/micro-fibrillation and orientation than the core layer. Compared with the macropart, the micropart exhibits increased PCL crystallinity and remarkably enhanced PLA crystallization capability. μIM also leads to a higher PLA degradation degree than CIM. In addition, the PLA/PCL blend micropart shows much higher mechanical performance and much more obvious double yielding phenomenon than the macropart.

Graphical abstract: In situ nano-fibrillation of microinjection molded poly(lactic acid)/poly(ε-caprolactone) blends and comparison with conventional injection molding

Article information

Article type
Paper
Submitted
02 Aug 2015
Accepted
26 Oct 2015
First published
26 Oct 2015

RSC Adv., 2015,5, 92905-92917

Author version available

In situ nano-fibrillation of microinjection molded poly(lactic acid)/poly(ε-caprolactone) blends and comparison with conventional injection molding

W. Ding, Y. Chen, Z. Liu and S. Yang, RSC Adv., 2015, 5, 92905 DOI: 10.1039/C5RA15402B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements