Issue 8, 2015

Sensitive high resolution ion microprobe – stable isotope (SHRIMP-SI) analysis of water in silicate glasses and nominally anhydrous reference minerals

Abstract

Low-level water measurements of geological materials are fundamental in understanding the volatile inventories of the Earth from the mantle to crustal reservoirs. Here we describe the development of microanalytical techniques using the new SHRIMP SI ion microprobe to measure the abundances of OH (as a proxy for water) in volcanic glass and nominally anhydrous minerals (NAMs). Samples were first analysed at the Carnegie Institute of Washington (CIW) on their Cameca ims-6f with calibrations based on previous FTIR and manometry analyses. SHRIMP SI is a large geometry ion microprobe and is currently mainly used for O and S isotope analyses. The analytical protocol used here incorporates multiple collection of 16O and 16O1H allowing rapid measurements. A single calibration line incorporating all glasses and NAMs for the SHRIMP SI allows calibration of 16O1H/16O to H2O over a wide range in concentration (50 to 15 000 ppm H2O). This calibration line has around a 10% uncertainty, which appears to be limited only by sample heterogeneity. The current background for SHRIMP analysis is between 20–40 ppm but this is expected to improve with improved pumping on the source chamber. A current limitation to water analysis of NAM samples, by any technique, is having a range of standard materials to enable OH calibration to absolute H2O concentrations. Data are presented for 7 NAM samples (2 olivines, 2 orthopyroxenes and 3 clinopyroxenes) that appear to be promising as potential standards for international laboratory H2O measurements. These NAM samples have been analysed and characterised here by SHRIMP SI, FTIR, EMP and the Cameca ims-6f ion microprobe at CIW. Four of these samples have previously been measured by manometry to determine absolute H2O concentrations.

Graphical abstract: Sensitive high resolution ion microprobe – stable isotope (SHRIMP-SI) analysis of water in silicate glasses and nominally anhydrous reference minerals

Supplementary files

Article information

Article type
Paper
Submitted
11 Feb 2015
Accepted
20 Apr 2015
First published
07 May 2015

J. Anal. At. Spectrom., 2015,30, 1706-1722

Author version available

Sensitive high resolution ion microprobe – stable isotope (SHRIMP-SI) analysis of water in silicate glasses and nominally anhydrous reference minerals

M. Turner, T. Ireland, J. Hermann, P. Holden, J. A. Padrón-Navarta, E. H. Hauri and S. Turner, J. Anal. At. Spectrom., 2015, 30, 1706 DOI: 10.1039/C5JA00047E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.