A flexible ion chromatography column-switching system with a switching time window (STW) calibration program for the determination of myo-inositol in infant formula by pulsed amperometric detection

Abstract

This study introduces a flexible ion chromatographic column-switching technique for the direct analysis of myo-inositol in infant formula samples by pulsed amperometric detection. The system, based on two pumps, two columns and three six-pore valves, allowed for free automatic switching between the switching time window (STW) calibration mode and analysis mode. Chromatographic parameters, including chromatographic columns, mobile phases, elution gradient, column-switching parameters, detector waveform parameters, etc., were optimized systematically for the analysis of myo-inositol in infant formula. In this method, both the pretreatment column and analytical column were arranged to be activated and regenerated during their idle time by optimizing the switching program of the three valves, thus increasing the efficiency of the method. The detection potential, E1, of the quadruple-potential waveform was also optimized and it was set to 0.027 V, which offered both excellent sensitivity and a stable baseline. By applying this optimized method to real samples, the determination of myo-inositol in infant formula was achieved in only 20 minutes, with a linear dynamic range from 0.05 μg mL−1 to 120 μg mL−1, and a limit of detection (LOD) (S/N = 3) of 2.5 μg g−1. The results demonstrate the feasibility of this method for routine analysis of myo-inositol in infant formula with the advantages of automation, simple pretreatment, low cost, good stability, and no use of organic reagents.

Graphical abstract: A flexible ion chromatography column-switching system with a switching time window (STW) calibration program for the determination of myo-inositol in infant formula by pulsed amperometric detection

Article information

Article type
Paper
Submitted
15 Jan 2015
Accepted
12 Feb 2015
First published
12 Feb 2015

Anal. Methods, 2015,7, 2830-2838

Author version available

A flexible ion chromatography column-switching system with a switching time window (STW) calibration program for the determination of myo-inositol in infant formula by pulsed amperometric detection

S. Zhang, L. Huang, H. Li, X. Chen, F. Wang, D. Zhang and Y. Zhu, Anal. Methods, 2015, 7, 2830 DOI: 10.1039/C5AY00118H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements