A low-cost forward and reverse blood typing device—a blood sample is all you need to perform an assay

Abstract

For all user-operated blood typing devices in today's market, including those designed by us in our previous research, a buffer-activation or buffer-washing step is required. The buffer-activation step, as is employed in some commercial blood typing devices, involves dissolving the antibodies deposited in the assaying zones of the device before the introduction of a blood sample for an assay. The buffer-washing step involves washing the blood sample in the assay zone in the end of the assay for result reporting. While all these devices work well, the activation or washing step does reduce the adaptability of those devices to resource-poor areas and under emergent circumstances. In this study, we designed a new device to perform forward and reverse blood typing assays without the buffer-activation or buffer-washing. Low-cost plastic slides were patterned to form channels containing dried grouping antibodies. Blood typing assays can be performed by simply placing a few microlitres of a blood sample into the channels and then tilting the slide. The sample flows along the channel under gravity, dissolving dried antibody and then spreading into a film, unveiling the reaction of red blood cells (RBCs) and antibodies. This device enables easy visual identification of the agglutinated and non-agglutinated RBCs in typically 1 minute. Both forward and reverse blood typing assays can be performed using this device. To optimize the device design, the antibody dissolution profile, assay sensitivity, and device longevity were investigated in this work.

Graphical abstract: A low-cost forward and reverse blood typing device—a blood sample is all you need to perform an assay

Supplementary files

Article information

Article type
Paper
Submitted
17 Nov 2014
Accepted
06 Dec 2014
First published
15 Dec 2014

Anal. Methods, 2015,7, 1186-1193

Author version available

A low-cost forward and reverse blood typing device—a blood sample is all you need to perform an assay

M. Li, J. Tian, R. Cao, L. Guan and W. Shen, Anal. Methods, 2015, 7, 1186 DOI: 10.1039/C4AY02739F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements