Jump to main content
Jump to site search

Issue 5, 2013
Previous Article Next Article

The automation and optimization of solid phase extractioninductively coupled plasma mass spectrometry analysis for the high throughput determination of aqueous levels of U, Th, Np, Pu, and Am

Author affiliations

Abstract

The development of an automated chemical and mechanical sequence is presented for actinide analysis by inductively coupled plasma mass spectrometry (ICP-MS) using a column-based chromatographic system with TRU resin for matrix separation. The approach yields a robust method that allows for simple handling with high sample throughput for use in rapid response scenarios. Nanogram-level studies were carried out using ICP-MS with mono-isotopic spiked samples. Sample throughput was extrapolated to successfully handle over 2000 samples a day. This process includes a manual valency adjustment allowing for direct optimal loading while simultaneously minimizing sample dilution, an automated solid phase extraction platform, and a unique transfer system for flow through from the extraction to the ICP-MS detection platform. Bed volumes, reagent compositions, resin environments as well as volume and flow rates were optimized to increase recovery. Under optimal conditions the average recoveries over the range from 0.1 to 1.0 μg L−1 were 238U 106.3 ± 5.4%, 237Np 100.5 ± 2.3%, 242Pu 94.3 ± 5.2% and 232Th 109.2 ± 4.8%. Using synthetic urine as a complex matrix the recoveries were 238U 96.2 ± 1.6%, 237Np 95.4 ± 1.7%, 242Pu 81 ± 2.4%, 232Th 98.8 ± 1.7% and 241Am 53 ± 3.6% for samples at the 1 μg L−1 level co-eluted with a 0.5 M HCl/0.3 M oxalic acid solution. These high recoveries were obtained while successfully removing 99.999% of monitored matrix ion constituents and minimizing reagent volumes, culminating in the development of a method that allows for rapid onsite handling of a large number of samples while maintaining high recovery and consistency inherent to automation.

Graphical abstract: The automation and optimization of solid phase extraction inductively coupled plasma mass spectrometry analysis for the high throughput determination of aqueous levels of U, Th, Np, Pu, and Am

Back to tab navigation

Publication details

The article was received on 30 Nov 2012, accepted on 28 Feb 2013 and first published on 01 Mar 2013


Article type: Paper
DOI: 10.1039/C3JA30352G
J. Anal. At. Spectrom., 2013,28, 711-718

  •   Request permissions

    The automation and optimization of solid phase extraction inductively coupled plasma mass spectrometry analysis for the high throughput determination of aqueous levels of U, Th, Np, Pu, and Am

    J. J. Charlton, M. J. Sepaniak, A. K. Sides, T. G. Schaaff, D. K. Mann and J. A. Bradshaw, J. Anal. At. Spectrom., 2013, 28, 711
    DOI: 10.1039/C3JA30352G

Search articles by author