Issue 17, 2013

Non-contact halogen lamp heating assisted LTP ionization miniature rectilinear ion trap: a platform for rapid, on-site explosives analysis

Abstract

A platform consisting of a halogen lamp, a low temperature plasma (LTP) probe, and a miniature rectilinear ion trap mass spectrometer (RIT-MS) has been constructed and evaluated to detect organic and inorganic explosives on solid surfaces. This platform features two attractive characteristics: high sensitivity for the explosives with low volatility, and rapid analysis speed for the explosives on large surface areas. With non-contact heating by the halogen lamp, the signal intensities for the explosives with relatively high volatility were improved by over an order of magnitude, compared to those obtained at room temperature; and even more, the explosives with low volatility, which could hardly be detected at room temperature, were able to be readily identified. The limits of detection (LODs) of the selected explosives were all at the picogram level (e.g., 10 pg and 20 pg for TNT and RDX, respectively) with a heating time of 3 s. Using manual surface swabbing, the analysis of explosives on a large surface area (7.5 cm × 2.5 cm) was accomplished within 10 s, and an acceptable sensitivity could be acquired; additionally, inorganic explosives (black powder and firecracker) were successfully detected. Without any sample pretreatment, the platform was used to analyze the wastewater from an explosives factory, confirming the existence of 2,4,6-trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DNT), and 2,6-dinitrotoluene (2,6-DNT), and the concentration of TNT was determined to be 5 ng mL−1. All these results indicated that the proposed platform was a promising technique for security monitoring and environmental analysis.

Graphical abstract: Non-contact halogen lamp heating assisted LTP ionization miniature rectilinear ion trap: a platform for rapid, on-site explosives analysis

Article information

Article type
Paper
Submitted
20 Mar 2013
Accepted
14 May 2013
First published
14 May 2013

Analyst, 2013,138, 5068-5073

Non-contact halogen lamp heating assisted LTP ionization miniature rectilinear ion trap: a platform for rapid, on-site explosives analysis

W. Chen, K. Hou, X. Xiong, Y. Jiang, W. Zhao, L. Hua, P. Chen, Y. Xie, Z. Wang and H. Li, Analyst, 2013, 138, 5068 DOI: 10.1039/C3AN00555K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements