Issue 12, 2012

Determination of polycyclic aromatic hydrocarbons on SMA-EGDMA polymeric mononlith column by capillary electrochromatography

Abstract

In this study, a reversed-phase C18 polymeric monolith column of stearyl methacrylate-co-ethylene glycol dimethacrylate (SMA-EGDMA) was prepared and used to separate polycyclic aromatic hydrocarbons (PAHs) by capillary electrochromatography. The prepared column exhibits a good efficiency of 20,000 plates per m for naphthalene. The separation conditions for PAHs were systematically optimized. The optimized condition for the mobile phase was acetonitrile/10 mM ammonium acetate, pH 7 (80/20, v/v), and the applied voltage was set at 28 kV. Subsequently, an on-line concentration was employed to the CEC separation and by changing injection time a dramatic improvement was observed in the detection sensitivity up to 50-fold enhancement, achieving nanogram level with almost no loss of resolution. Six polycyclic aromatic hydrocarbons (naphthalene, fluorene, phenanthrene, fluoranthene, pyrene, benz[a]anthracene) showed good linearity with linear correlation coefficient R > 0.99. Reproducibility of the column was investigated. Relative standard deviations of migration time (n = 5) and peak area (n = 5) were in the range of 4.71–4.93% and 4.88–6.65%, respectively, for the six polycyclic aromatic hydrocarbons on the SMA-EGDMA polymeric monolith column. The percentage recoveries of six PAHs including naphthalene, fluorene, phenanthrene, fluoranthene, pyrene and benz[a]anthracene in East Lake water samples at three different concentrations are 93.7–102.5, 98.6–108.1, 92.6–105.9, 95.2–102.1, 91.8–105.4, and 100.9–103.7, respectively.

Graphical abstract: Determination of polycyclic aromatic hydrocarbons on SMA-EGDMA polymeric mononlith column by capillary electrochromatography

Article information

Article type
Paper
Submitted
28 Aug 2012
Accepted
11 Oct 2012
First published
11 Oct 2012

Anal. Methods, 2012,4, 4140-4145

Determination of polycyclic aromatic hydrocarbons on SMA-EGDMA polymeric mononlith column by capillary electrochromatography

J. Zhang, T. Bao and Z. Chen, Anal. Methods, 2012, 4, 4140 DOI: 10.1039/C2AY25953B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.