Abstract

Chemical Oxygen Demand (COD) estimates the amount of organic oxidizable matter in wastewaters. It is a critical parameter for assessing the quality of effluents prior to discharge, in the design and operation of wastewater treatment plants, and in environmental modelling and monitoring. In this study COD was determined by a closed reflux titrimetric method according to 5220C, APHA, 21st edn, 2005. This method is applicable to COD values between 40 and 400 mg L−1 and chloride concentrations up to 2000 mg L−1. Chloride interference is a serious problem in COD measurement for wastewaters containing low organic matter concentrations. The reliability of the results depends on a proper validation of the measurement procedure that includes the calculation and evaluation of the measurement uncertainty. This study develops a practical, understandable and simple way for calculating and assessing the Combined Standard Uncertainty (CSU) of COD measurement, mainly based on already existing quality control and validation data. The CSU assessment is based on the existing literature trueness and precision target limits, without any additional assumptions. Diagrams correlating the trueness of the COD measurement mean values with different chloride concentrations and the laboratory control charts' limits offer a tool for improving the performance of the determination and define the method application area. The validation data that were obtained in our laboratory (accredited according to ISO 17025) and the proposed methodology for CSU calculation were verified in the frame of intra and inter-laboratory measurements.

Graphical abstract: An easy uncertainty evaluation of the COD titrimetric analysis in correlation with quality control and validation data. Method applicability region

Article information

Article type
Paper
Submitted
12 Apr 2012
Accepted
25 Oct 2012
First published
26 Oct 2012

Anal. Methods, 2012,4, 4204-4212

An easy uncertainty evaluation of the COD titrimetric analysis in correlation with quality control and validation data. Method applicability region

E. Amanatidou, E. Trikoilidou, G. Samiotis, N. P. Benetis and N. Taousanidis, Anal. Methods, 2012, 4, 4204 DOI: 10.1039/C2AY25687H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements