Issue 9, 2012

Sensitive determination of polybrominated diphenyl ethers in environmental water samples with etched stainless steel wire based on solid-phase microextraction prior to gas chromatography-mass spectrometry

Abstract

Solid-phase microextraction (SPME) is a solvent-free sample pretreatment technique and has attracted great attention in many application fields. The potential of etched stainless steel wire as SPME adsorbent for the enrichment of organic pollutants has been investigated in recent years. The goal of this work was to investigate the feasibility of using etched stainless steel wire as SPME adsorbents to enrich polybrominated diphenyl ethers (PBDEs) at trace levels, which are new typical persistent organic pollutants in the environment. Extraction conditions that maybe influence the extraction efficiency such as extraction time, agitation speed, ionic strength, and desorption conditions were investigated and optimized in detail. The experimental results exhibited the good linear relationship over the range of 1–200 ng L−1, and the precisions were 5.2–9.5% under the optimal conditions. The limits of detection could reach 0.2–0.6 ng L−1. Satisfactory results were obtained when the present method was applied to determine the seven PBDEs in real world water samples with the recoveries over the range of 77–118%. All these results indicated that etched stainless steel wire as SPME adsorbents coupled to gas chromatography-negative chemical ionization mass spectrometry (GC-NCI-MS) was an excellent method for the rapid analysis of PBDEs at trace levels in the environment.

Graphical abstract: Sensitive determination of polybrominated diphenyl ethers in environmental water samples with etched stainless steel wire based on solid-phase microextraction prior to gas chromatography-mass spectrometry

Article information

Article type
Paper
Submitted
12 May 2012
Accepted
12 Jun 2012
First published
13 Jun 2012

Anal. Methods, 2012,4, 2908-2913

Sensitive determination of polybrominated diphenyl ethers in environmental water samples with etched stainless steel wire based on solid-phase microextraction prior to gas chromatography-mass spectrometry

X. Chen, C. Cheng, X. Wang and R. Zhao, Anal. Methods, 2012, 4, 2908 DOI: 10.1039/C2AY25483B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements