Issue 22, 2012

A novel amplification strategy for genotyping with liquid chromatography-electrospray ionization mass spectrometry

Abstract

Among numerous available genotyping techniques, mass spectrometry (MS) based methods play a major role in providing high quality genotype data at reasonable costs for research and diagnostics, e.g. for pharmacogenetic applications. Ion-pair reversed-phase liquid chromatography hyphenated to electrospray ionization time-of-flight MS (ICEMS) is, for example, a powerful instrument that allows a direct characterization of complex mixtures of polymerase chain reaction (PCR) amplified DNA fragments. Current limitations of PCR-ICEMS genotyping are mainly concerned with the multiplex PCR set-up. Assay development often requires time-consuming primer design and intensive optimization of PCR conditions. To overcome this restraint, a robust amplification strategy originally combined with arrayed primer extension genotyping was transferred and adapted to ICEMS genotyping. The modifications involved limitation of the primer length, application of two universal sequences and amplification with an appropriate DNA polymerase. To demonstrate the applicability of the novel amplification strategy for ICEMS, a 23-plex pharmacogenetic genotyping assay was developed. After slight optimization steps, an efficient and quantitatively balanced amplification of all targeted markers was achieved, resulting in a convenient characterization of the multiplexed PCR fragments with ICEMS. Expenditure of time, costs and hands-on work associated with assay design and optimization was dramatically lowered compared to previous multiplex PCR-ICEMS assays. The developed 23-plex assay was applied in a pharmacogenetic study including 284 individuals (genotype call rate 99.0%). A total of 399 SNPs were retyped by Sanger sequencing (concordance rate 99.8%). The PCR-ICEMS assay turned out to be an accurate, reliable, cost-effective and a ready-to-use tool for pharmacogenetic genotyping.

Graphical abstract: A novel amplification strategy for genotyping with liquid chromatography-electrospray ionization mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
02 Apr 2012
Accepted
31 Aug 2012
First published
31 Aug 2012

Analyst, 2012,137, 5325-5333

A novel amplification strategy for genotyping with liquid chromatography-electrospray ionization mass spectrometry

B. Beer, K. Krjutškov, R. Erb, T. Viltrop and H. Oberacher, Analyst, 2012, 137, 5325 DOI: 10.1039/C2AN35440C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements