Issue 20, 2011

Rapid and ultrasensitive E. coli O157:H7 quantitation by combination of ligandmagnetic nanoparticles enrichment with fluorescent nanoparticles based two-color flow cytometry

Abstract

A novel, fast and sensitive determination strategy for E. coli O157:H7 has been developed by combination of ligandmagnetic nanoparticles (LMNPs) enrichment with a fluorescent silica nanoparticles (FSiNPs) based two-color flow cytometry assay (LMNPs@FSiNPs-FCM). E. coli O157:H7 was first captured and enriched through the lectin concanavalin A (Con A) favored strong adhesion of E. coli O157:H7 to the mannose-conjugated magnetic nanoparticles. The enriched E. coli O157:H7 was further specially labeled with goat anti-E. coli O157:H7 antibody modified RuBpy-doped FSiNPs, and then stained with a nucleic acid dye SYBR Green I (SYBR-I). After dual-labeling with FSiNPs and SYBR-I, the enriched E. coli O157:H7 was determined using multiparameter FCM analysis. With this method, the detection sensitivity was greatly improved due to the LMNPs enrichment and the signal amplification of the FSiNPs labelling method. Furthermore, the false positives caused by aggregates of FSiNPs conjugates and nonspecific binding of FSiNPs to background debris could be significantly decreased. This assay allowed the detection ofE. coli O157:H7 in PB buffer at levels as low as 7 cells mL−1. The total assay time including E. coli O157:H7 sample enrichment and detection was less than 4 h. An artificially contaminated bottled mineral water sample with a concentration of 6 cells mL−1 can be detected by this method. It is believed that the proposed method will find wide applications in biomedical fields demanding higher sensitive bacterial identification.

Graphical abstract: Rapid and ultrasensitive E. coli O157:H7 quantitation by combination of ligandmagnetic nanoparticles enrichment with fluorescent nanoparticles based two-color flow cytometry

Supplementary files

Article information

Article type
Paper
Submitted
19 May 2011
Accepted
02 Jul 2011
First published
22 Aug 2011

Analyst, 2011,136, 4183-4191

Rapid and ultrasensitive E. coli O157:H7 quantitation by combination of ligandmagnetic nanoparticles enrichment with fluorescent nanoparticles based two-color flow cytometry

X. He, L. Zhou, D. He, K. Wang and J. Cao, Analyst, 2011, 136, 4183 DOI: 10.1039/C1AN15413C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.