Issue 9, 2010

8-Hydroxyquinoline-5-sulfonic acid as the modifier for the determination of trace elements in cereals by slurry sampling electrothermal vaporization ICP-MS

Abstract

Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine V, Cr, Co, Ni, Cu, Zn, Se, Cd, Hg and Pb in cereal samples. 8-hydroxyquinoline-5-sulfonic acid (8-HQ-5-SA) was used as the modifier to increase the volatility of the elements studied which makes the quantification possible using external calibration. The influences of instrument operating conditions and slurry preparation on the ion signals were studied to get better sensitivity of the elements studied and also similar sensitivity between slurry and aqueous solution. In this study, Cr, Cu, Zn and Se were determined under dynamic reaction cell (DRC) mode, while V, Co, Ni, Cd, Hg and Pb were determined under standard mode separately. The background ions at the masses m/z 52 and 80 were reduced in intensity significantly by using 1.0 mL min−1 CH4 as reaction cell gas in the DRC. This method has been applied to the determination of V, Cr, Co, Ni, Cu, Zn, Se, Cd, Hg and Pb in NIST SRM 1568a Rice Flour and SRM 1567a Wheat Flour reference materials and two cereal samples purchased from the local market. Analysis of the reference material agreed with the certified values. The results for the real world cereal samples were also found to be in good agreement with the pneumatic nebulization ICP-MS results of the sample solutions. The method detection limit was 1.3, 2.1, 3.6, 4.3, 6.8, 16, 1.7, 0.6, 0.8 and 2.6 ng g−1 for V, Cr, Co, Ni, Cu, Zn, Se, Cd, Hg and Pb, respectively, in original cereal samples.

Graphical abstract: 8-Hydroxyquinoline-5-sulfonic acid as the modifier for the determination of trace elements in cereals by slurry sampling electrothermal vaporization ICP-MS

Article information

Article type
Paper
Submitted
09 Jun 2010
Accepted
14 Jun 2010
First published
28 Jul 2010

Anal. Methods, 2010,2, 1310-1315

8-Hydroxyquinoline-5-sulfonic acid as the modifier for the determination of trace elements in cereals by slurry sampling electrothermal vaporization ICP-MS

S. Huang and S. Jiang, Anal. Methods, 2010, 2, 1310 DOI: 10.1039/C0AY00367K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements