Issue 10, 2009

Quantification of major and trace elements in water samples by ICP-MS and collision cell to attenuate Ar and Cl-based polyatomic ions

Abstract

Inductively coupled plasma mass spectrometry (ICP-MS) is the best fitted analytical technique for multi-element analysis of waters, because of its low detection limits. One limitation is the polyatomic interferences produced in the plasma and in the interface (e.g., 35Cl16O+ on 51V+, 40Ar16O+ on 56Fe+, 40Ar35Cl+ on 75As+ and 40Ar38Ar+ on 78Se+). These polyatomic ions can be significantly reduced by ion molecule interactions in a collision cell (CC). Several experiments done in a ICP-MS equipped with a CC pressurized by premixed H2 7% in He, under optimized gas flow rates, demonstrate the beneficial effect of KED to suppress Ar and Cl-based interferences. These results are opposed to reports where the role of KED was denied. Under such conditions the background equivalent concentration of 51V, 52Cr, 56Fe, 63Cu, 75As and 78Se were improved by two orders of magnitude, allowing the quantification of these elements at low ng L−1 level, without the need for mathematical corrections. Moreover, we present results obtained with a multi-mode method of analysis for twenty eight elements in two water certified reference materials (CRM). In this method isotopes free from polyatomic interferences are measured in standard mode and interfered ones using CC mode. The certified and reference values were used to evaluate the analytical trueness, which was better than 5%, with all z-scores within the recommended limit. Intermediate precision was mostly better than 6% and method detection limits are fit for hydrogeochemical studies and to monitor regulated toxic trace elements in waters.

Graphical abstract: Quantification of major and trace elements in water samples by ICP-MS and collision cell to attenuate Ar and Cl-based polyatomic ions

Article information

Article type
Paper
Submitted
27 Jan 2009
Accepted
21 Jul 2009
First published
05 Aug 2009

J. Anal. At. Spectrom., 2009,24, 1406-1413

Quantification of major and trace elements in water samples by ICP-MS and collision cell to attenuate Ar and Cl-based polyatomic ions

A. J. Bueno Cotta and J. Enzweiler, J. Anal. At. Spectrom., 2009, 24, 1406 DOI: 10.1039/B901644A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements