Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry

Abstract

Axial and radial profiles of ion (Al+, V+, Cr+, Mn+, Fe+, Ni+, Co+, Cu+, Zn+, As+, Mo+, Sb+, La+, LaO+, Ce+ and CeO+) distribution in inductively coupled plasma mass spectrometry were examined for solutions containing 1% v/v HNO3 (i.e. 0.16 M) with and without 0.02 M NaNO3, KNO3, CsNO3, HI or HCl. None of the latter matrices induced a significant change in sample introduction efficiency compared to 1% v/v HNO3 alone. Nonetheless, although analyte signal suppression was predominant in the presence of the K and Cs matrices, 0.02 M Na induced an enhancement by 1.6 ± 0.3 across the mass range, which was irrespective of the analyte ionization potential (i.e. even analytes that should be completely ionized were enhanced). This may be rationalized using a Coulomb fission mechanism within the spray chamber, which shifts the droplet size distribution towards smaller ones that are then more efficiently transported through the spray chamber and ultimately result in more analyte ions in the plasma. Furthermore, desolvation of these smaller droplets is completed sooner in the ICP, as axial profiles of the oxide fraction of La and Ce were shifted lower in the plasma in the presence of a non-volatile ionic matrix (0.02 M NaNO3, KNO3, CsNO3) but were unaffected by 0.02 M HCl or HI. The broadened analyte radial profile in the presence of 0.02 M Na, which was observed at the optimum sampling depth for a 1% v/v HNO3 matrix, also points to earlier desolvation. These results suggest that the Coulomb fission mechanism may be significant with a conventional sample introduction system.

Graphical abstract: Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry

Article information

Article type
Paper
Submitted
06 Nov 2008
Accepted
11 Feb 2009
First published
27 Feb 2009

J. Anal. At. Spectrom., 2009,24, 469-475

Evidence supporting the occurrence of Coulomb fission during conventional sample introduction in inductively coupled plasma mass spectrometry

M. M. Fraser and D. Beauchemin, J. Anal. At. Spectrom., 2009, 24, 469 DOI: 10.1039/B819816K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements