Abstract

We propose a new type of micro/nano fluidic mixer based on non-equilibrium electrokinetics and demonstrate its mixing performance. We fabricate the device with two-step reactive ion etching, one for nanochannels and one for microchannels. Mixing is achieved by strong vortex structures formed near the micro/nano channel interface. We expect the proposed device to be beneficial in the development of micro total analysis systems, since it is simple in its design with minimal fabrication complications.

Graphical abstract: Non-equilibrium electrokinetic micro/nano fluidic mixer

Article information

Article type
Technical Note
Submitted
12 Nov 2007
Accepted
14 Feb 2008
First published
28 Feb 2008

Lab Chip, 2008,8, 625-628

Non-equilibrium electrokinetic micro/nano fluidic mixer

D. Kim, A. Raj, L. Zhu, R. I. Masel and M. A. Shannon, Lab Chip, 2008, 8, 625 DOI: 10.1039/B717268K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.