Abstract

When an instrument response is measured over a period of time changes in the signal intensity can occur. If this happens following the calibration of an instrument, in this instance using a multivariate model, subsequent use of the calibration model will most probably produce erroneous results, posing severe restrictions on the successful application of such models. However, it is possible to solve this problem by applying multivariate techniques that attempt to find a transformation function that acts on the measured response from a drifted instrument transforming it to that which would be obtained on the same instrument at the time of calibration. One multivariate technique capable of this, piecewise direct standardisation (PDS) allows the full spectrum to be utilised without restriction, however it is shown here that it is possible to reduce the number of wavelengths and combine drift correction with variable selection using a previously published method. The synthetic calibration and test solutions used contained varying concentrations of the analytes Pt, Pd, Rh and the matrix elements Al, Mg, Ce, Zr, Ba, In, Sc and Y. Piecewise direct standardisation was then applied to a dataset comprising a set of variables selected on the basis of the importance of their respective partial least squares (PLS) regression coefficients. For Pt, Pd, and Rh, respectively, the relative root mean square percentage error (RRMSE%) after the application of PDS, was 4.14, 3.03 and 1.88%, compared to 73.04, 44.39 and 28.06% without correction; it was evident that there was a clear bias in the uncorrected concentrations for all three analytes. Confidence intervals for the analytes also showed a significant improvement with the application of PDS, and was most noticeable for Rh and Pt.

Graphical abstract: The application of piecewise direct standardisation with variable selection to the correction of drift in inductively coupled atomic emission spectrometry

Article information

Article type
Paper
Submitted
31 Mar 2006
Accepted
17 Jul 2006
First published
07 Aug 2006

J. Anal. At. Spectrom., 2006,21, 1045-1052

The application of piecewise direct standardisation with variable selection to the correction of drift in inductively coupled atomic emission spectrometry

M. L. Griffiths, D. Svozil, P. Worsfold and E. Hywel Evans, J. Anal. At. Spectrom., 2006, 21, 1045 DOI: 10.1039/B604728A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements