Issue 10, 2006

Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters

Abstract

The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 ± 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 ± 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7–20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.

Graphical abstract: Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters

Article information

Article type
Paper
Submitted
03 May 2006
Accepted
04 Aug 2006
First published
06 Sep 2006

J. Environ. Monit., 2006,8, 1006-1013

Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters

J. E. Farnsworth, S. M. Goyal, S. Won Kim, T. H. Kuehn, P. C. Raynor, M. A. Ramakrishnan, S. Anantharaman and W. Tang, J. Environ. Monit., 2006, 8, 1006 DOI: 10.1039/B606132J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.