High precision Hg isotope analysis of environmental samples using gold trap-MC-ICP-MS

Abstract

Precise and accurate analysis of Hg isotope compositions in environmental samples can be an invaluable tool in investigating Hg cycles in the environment. We have developed a method for high precision Hg isotope analysis using a gold trap sample introduction system coupled to a Thermo Finnigan MC-ICP-MS. Environmental samples were pyrolyzed at high temperature and Hg released from the samples was collected in gold traps. The Hg on the gold traps was then thermally released into a sample introduction system coupled to an MC-ICP-MS. The sample introduction system extended the Hg signal duration, which would otherwise be a short transient signal if released directly into the plasma, thus significantly improving the precision and accuracy of Hg isotope measurement. Instrumental mass bias was corrected using a Tl internal isotopic standard and a “standard–sample–standard” bracketing technique. Based on the long term measurement of NIST-2225 elemental Hg standard, the external precision ranges from 44 to 109 ppm for 201Hg/202Hg and 199Hg/202Hg ratios, respectively. The average mass bias corrected Hg isotope ratios for NIST-2225 are: 198Hg/202Hg = 0.335 948 ± 87 (2σ), 199Hg/202Hg = 0.567 423 ± 109, 200Hg/202Hg = 0.776 552 ± 93, and 201Hg/202Hg = 0.443 085 ± 44. These ratios agree within error with the IUPAC values issued in 1983, but differ significantly from the IUPAC values issued in 1997. Our data suggest that there are significant Hg isotope variations among different environmental samples. Specifically, organic samples containing predominantly methylmercury appear to be enriched in light isotopes compared with samples with inorganic Hg, suggesting that biomethylation may play an important role in Hg isotope fractionation in the environment.

Graphical abstract: High precision Hg isotope analysis of environmental samples using gold trap-MC-ICP-MS

Article information

Article type
Paper
Submitted
06 Dec 2004
Accepted
16 Mar 2005
First published
03 May 2005

J. Anal. At. Spectrom., 2005,20, 515-522

High precision Hg isotope analysis of environmental samples using gold trap-MC-ICP-MS

Q. Xie, S. Lu, D. Evans, P. Dillon and H. Hintelmann, J. Anal. At. Spectrom., 2005, 20, 515 DOI: 10.1039/B418258H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements