Issue 12, 2005

Impaction collection and slurry sampling for the determination of arsenic, cadmium, and lead in sidestream cigarette smoke by inductively coupled plasma-mass spectrometry

Abstract

The slurry sampling technique has been applied for the determination of arsenic, cadmium and lead in sidestream cigarette smoke condensate (SS CSC) by inductively coupled plasma mass spectrometry (ICP-MS). The smoke collection system consists of a “fishtail” chimney in conjunction with an impaction trap and a mixed cellulose ester (MCE) backup filter for the SS CSC collection. The smoke condensates, collected at three different regions of the system (i.e. the inner wall of the chimney, the impaction trap and the MCE filter), were individually prepared and analyzed and showed that about 70 and 20% of Cd and Pb, respectively, were trapped by the impaction trap and the MCE filter with less than 5% trapped by the chimney. In contrast, about 60% of As was trapped by the impactor and a relatively high percentage of As, about 30%, was deposited onto the inner wall of the chimney. The uneven distribution of trace metals at each collection stage strongly suggested that the composition of smoke aerosol and the associated physical form of the analytes may be different. The yields of As, Cd and Pb for the sidestream cigarette smoke of the 1R4F reference cigarette were 29.5 ± 2.4, 421 ± 6.6 and 46.4 ± 0.9 ng cigarette−1 (n = 3) respectively, when the cigarette was smoked according to the smoking regime: 45 mL puff volume of 2-s puff duration at an interval of 30 s with 50% ventilation holes covered. The analytical results for the slurry sampling technique were also compared with other sample preparation techniques and show good agreement.

Graphical abstract: Impaction collection and slurry sampling for the determination of arsenic, cadmium, and lead in sidestream cigarette smoke by inductively coupled plasma-mass spectrometry

Article information

Article type
Paper
Submitted
27 Jun 2005
Accepted
07 Oct 2005
First published
21 Oct 2005

J. Environ. Monit., 2005,7, 1349-1354

Impaction collection and slurry sampling for the determination of arsenic, cadmium, and lead in sidestream cigarette smoke by inductively coupled plasma-mass spectrometry

M. J. Chang, K. Walker, R. L. McDaniel and C. T. Connell, J. Environ. Monit., 2005, 7, 1349 DOI: 10.1039/B509048B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements