Issue 6, 2004

Rapid analysis for plutonium-239 in 1 ml of urine by magnetic sectorinductively coupled plasma mass spectrometry with a desolvating introduction system

Abstract

The Centers for Disease Control and Prevention has a mission to protect and promote public health, which includes investigation of environmental exposures to toxic substances that could threaten health. Plutonium is an environmentally available substance that is chemically and radiologically toxic and represents a potential health threat from excessive exposure. Inductively coupled plasma mass spectrometry (ICP-MS) is a sensitive method for assessing environmental or unintentional exposure to these and other actinides. We report here a magnetic sector instrument method in which a desolvating introduction system is used to provide rapid, sensitive emergency response analysis for 239Pu in only 1 mL of urine without digestion or coprecipitation. 239Pu was separated from U and interfering urine organic substances by solid phase extraction. The within run limit of detection (LOD) was 0.16 fg mL−1 for 1 mL of urine even though originally spiked to 1018 ng L−1 of depleted U. A more rigorous LOD of 1.4 fg mL−1239Pu was based on 3 “total” standard deviations in the presence of the same U concentration. At below 106 atoms of 239Pu detectable in 1 mL of urine, this method is sufficiently sensitive for elevated emergency exposure assessment with high throughput. The precision for 10 duplicate samples was within 3.7% relative “total” standard deviation (RSD, within and between run) for a 9.96 fg mL−1239Pu-spiked urine sample and within 2.2% for a 99.6 fg mL−1239Pu-spiked urine sample. The method was demonstrated to be accurate within 2.6% of the Los Alamos National Laboratories target value at 99.6 fg mL−1, to within 1.0% of target value at 9.96 fg mL−1 and within 1.2% at 0.996 fg mL−1, just below the method LOD.

Article information

Article type
Paper
Submitted
23 Dec 2003
Accepted
12 Mar 2004
First published
20 May 2004

J. Anal. At. Spectrom., 2004,19, 762-766

Rapid analysis for plutonium-239 in 1 ml of urine by magnetic sector inductively coupled plasma mass spectrometry with a desolvating introduction system

R. S. Pappas, B. G. Ting and D. C. Paschal, J. Anal. At. Spectrom., 2004, 19, 762 DOI: 10.1039/B316851D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements