Two simple flow injection (FI) systems were used for mercury speciation analysis in slurried fish tissue samples by cold vapor-atomic absorption spectrometry (CV-AAS). The solid samples were first suspended in hydrochloric acid containing Triton X-100 as dispersing agent, and then the slurries were injected in an acid carrier stream, which was either sequentially mixed with sulfuric acid, potassium persulfate oxidizing agent and stannous chloride reducing agent streams or merged with sodium borohydride reducing agent stream. Mercury speciation analysis was carried out as function of the oxidation coil temperature or sodium borohydride concentration, respectively. The detection limit of the method was 57 and 67 ng gāˆ’1, referred to dry weight, using the FI system with on-line oxidation for inorganic mercury and total mercury determination, respectively. Nevertheless, the FI system without on-line oxidation resulted in being simpler, faster and more sensitive for inorganic mercury and total mercury determination. Furthermore, the last system permitted the separate determination of methylmercury and inorganic mercury by selecting an adequate hydrochloric acid concentration in the suspension medium and the suitable sodium borohydride reducing agent. The detection limit of the method was 4.04, 0.977 and 11.0 ng gāˆ’1, referred to dry weight, for total mercury, inorganic mercury and methylmercury determination, respectively. Both FI methodologies were validated using two fish tissue certified reference materials, NRC DOLT-2 and NRC DORM-2, obtaining results in good agreement with the certified values, and were applied to the analysis of two real mussel tissue samples.

Article information

Article type
Paper
Submitted
14 Nov 2002
Accepted
06 Jan 2003
First published
21 Jan 2003

J. Anal. At. Spectrom., 2003,18, 268-273

Evaluation of two flow injection systems for mercury speciation analysis in fish tissue samples by slurry sampling cold vapor atomic absorption spectrometry

S. Río Segade and J. F. Tyson, J. Anal. At. Spectrom., 2003, 18, 268 DOI: 10.1039/B211282P

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements