Abstract

This paper describes a preliminary comparison of radial and axial excitation fluorescence within the ICP utilising hollow cathode lamps (HCLs) and narrow band-width light emitting diodes (LEDs) as sources. Univariate searches were used to optimise various plasma parameters, i.e., forward power, viewing height ALC, plasma, nebuliser and auxiliary gas flow rates, and various excitation source parameters, i.e., modulation frequency, duty cycle and peak current for each of the elements studied (Ba, Li, Mg and Na). Calibrations showed excellent linearity over five orders of magnitude (R2 = 0.99995–1.0000) with precision better than 5% RSD. Vertical profiles of the plasma, using radial excitation, were obtained for Ba and Mg using HCLs and for Li and Na using LEDs. Limits of detection were found to be 27.6, 0.51, 0.43 and 0.20 µg l−1 for Ba, Li, Mg and Na, respectively. Using the optimum conditions for Li and Na, vertical profiles of the plasma were obtained using axial excitation with the more intense LEDs. Two different excitation lens systems were investigated in the axial mode: a focusing lens and a collimating lens. The relatively sharp profiles and optimum viewing heights ALC obtained for each analyte studied were identical using both radial and axial excitation fluorescence (circa 60–80 mm at forward powers of 475–750 W and injector flow rates of 2.0–2.5 l min−1). The axial LODs obtained under these conditions were found to be 1.12 and 0.70 µg L−1, and 5.3 and 3.1 µg L−1 for Li and Na, using a focusing and collimating lens system, respectively. The potential for increased sensitivity and lower limits of detection is discussed using the novel axial excitation system. ‘Temperature’ measurements (Texc and Trot) determined under fluorescence conditions both gave values in the region 2500–3000 K, indicating a plasma operating closer to LTE.

Article information

Article type
Paper
Submitted
09 Sep 2002
Accepted
08 Nov 2002
First published
21 Nov 2002

J. Anal. At. Spectrom., 2003,18, 44-48

A preliminary comparison of radial and axial excitation fluorescence in the ICP using non-laser sources

A. Young, L. Pitts, S. Greenfield and M. Foulkes, J. Anal. At. Spectrom., 2003, 18, 44 DOI: 10.1039/B208794B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements