Issue 5, 2003

Artifact evidence in carbonyl compound sampling using the enclosure technique with cuvette system

Abstract

Biogenic hydrocarbon emission rates from individual plant species have been estimated experimentally placing small plants or branches in enclosures and measuring the emission rates of the compounds. All-Teflon chambers (cuvettes) where air samples are drawn through tubes packed with adsorbents, have been commonly used for plant enclosure. Sampling of carbonyl compounds emitted from plants has been done using 2,4-dinitrophenylhydrazine coated particles and the derivative carbonyl compounds have been analyzed by HPLC-UV. In this work, the enclosure technique using a cuvette for measurements of carbonyl compound emissions from plants was evaluated. Blank measurements in an empty cuvette have revealed quite different results for experiments performed under laboratory and field conditions. Rigorous univariate statistical analysis of the data obtained indicate that the analytical procedure to determine carbonyl compounds at trace levels in emission samples using the cuvette may lead to positive artifacts during field sampling. This analysis applied to laboratory measurements showed no difference in the results for the cuvette and external lines. Multivariate statistical calculations point out that solar light intensity accounts for the high carbonyl compound levels, especially for acetaldehyde, in the empty cuvette.

Article information

Article type
Paper
Submitted
09 May 2003
Accepted
15 Jul 2003
First published
30 Jul 2003

J. Environ. Monit., 2003,5, 795-801

Artifact evidence in carbonyl compound sampling using the enclosure technique with cuvette system

S. O. Pisani, R. E. Bruns, P. C. Vasconcellos and L. R. F. Carvalho, J. Environ. Monit., 2003, 5, 795 DOI: 10.1039/B305231C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight