Practical considerations when using radio frequency-only quadrupole ion guide for atmospheric pressure ionization sources with time-of-flight mass spectrometry

Abstract

Construction details and performance evaluation of a radio frequency (rf)-only quadrupole ion guide for use with an electrospray ionization time-of-flight mass spectrometer is presented in this paper. Angiotensin III and cytochrome c were used in these experiments to investigate the ion transmission properties of the rf-only quadrupole for different m/z species. In addition, influence of ion kinetic energies along with the characteristic fragmentation due to collision induced dissociation (CID) were studied. These experiments demonstrate that the transmissions of different m/z ions were not only dependent on the frequency and magnitude of the rf waveform, which is similar to a high vacuum rf-only quadrupole ion guide, but also on the pressure inside the quadrupole chamber. For the pressure range tested, low m/z ions are better focused with increasing pressure. As expected, transmission of ions are subject to space charge limitations when significant numbers of ions are focused on the axis of the quadrupole. It is also observed that CID results are related to transverse motion and longitude motion of ions inside the quadrupole region. Consequently, CID is useful for fragmentation of linear peptides and it is not effective (in present configuration) for large bulky proteins. The kinetic energy of ions that enter the repelling region of the TOFMS is ultimately determined by the ensemble effect resulting from the dc bias potential of the quadrupole (the dominant factor), skimmer-2, pressure inside the quadrupole chamber, and jet expansion. While this system is tested with an ESI source, the operational principle and design criteria are directly applicable for improving other atmospheric pressure ionization sources with time-of-flight mass analyzers such as an inductively coupled plasma ion source.

Article information

Article type
Paper
Submitted
17 Sep 2002
Accepted
22 Jan 2003
First published
17 Feb 2003

Analyst, 2003,128, 273-280

Practical considerations when using radio frequency-only quadrupole ion guide for atmospheric pressure ionization sources with time-of-flight mass spectrometry

W. Hang, C. Lewis and V. Majidi, Analyst, 2003, 128, 273 DOI: 10.1039/B209109G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements