Analyte- and matrix-dependent elemental response variations in laser ablation inductively coupled plasma mass spectrometry

Part 2.Implications for multi-element analyses

Abstract

Given that laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has the potential to directly determine the concentrations of some 80 elements in solid samples, the fact that most applications are limited to considerably smaller numbers of analytes is indicative of the inherent problems with calibration. These stem from elemental response variations, both between analytes in any given sample and between matrices for any given analyte. Although response variations are often attributed to differences in ablation or transport efficiencies, there have also been indications that some degree of elemental fractionation may occur in the ICP. The results of the present investigations demonstrate that the ICP is the predominant source of fractionation, and thus response variations are related to the thermodynamic properties of the elements and their host particles. By studying analyte response as a function of carrier gas flow rate (so called flow rate plots) in 16 matrices, patterns in the behaviour of the elements in LA-ICP-MS could be clearly discerned and used for classification. Three groups of elements displaying consistent behavioural patterns over all matrices were identified from these studies: Group A, comprising refractory elements with high oxide bond dissociation enthalpies; Group B, including the rare and heavier alkaline earth (Ca, Sr, Ba) elements; and Group C, consisting of volatile or low mass elements. As each group exhibits decidedly different optimum flow rates and flow rate plot shapes which, with the exception of the group C elements, also depend on the matrix, the utility of LA-ICP-MS for multi-element analyses is severely compromised. In fact, quantitative determination of a wide range of analytes demands that calibration factors be established for at least one element from each group, as well as for all elements that could not be satisfactorily classified. This classification may serve as a guide in the selection of suitable internal standards for LA-ICP-MS, at least for certain groups of analytes. Examples are also given showing how flow rate plots can be employed to predict the adequacy of selected internal standards or solid standard materials for calibration.

Article information

Article type
Paper
Submitted
07 Jun 2002
Accepted
19 Aug 2002
First published
06 Sep 2002

J. Anal. At. Spectrom., 2002,17, 1231-1239

Analyte- and matrix-dependent elemental response variations in laser ablation inductively coupled plasma mass spectrometry

I. Rodushkin, M. D. Axelsson, D. Malinovsky and D. C. Baxter, J. Anal. At. Spectrom., 2002, 17, 1231 DOI: 10.1039/B205547C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements