Issue 1, 2002

Abstract

Interest in possible sources of perchlorate (ClO4) that could lead to environmental release has been heightened since the Environmental Protection Agency placed this anion on its Contaminant Candidate List for drinking water. Although recent investigations have suggested that fertilizers are minor contributors to environmental perchlorate contamination overall, there is still interest in screening commercial products for possible contamination and quantitating perchlorate when it is found. Ion chromatography (IC) has been used for this application owing to its speed, low detection limits, widespread availability, and moderate ruggedness relative to other techniques. However, fertilizer matrixes complicate the IC analysis relative to potable water matrixes. In this study, the performance of poly(vinyl alcohol) gel resin IC columns (100 mm and 150 mm) was evaluated for fertilizer matrixes using method EPA/600/R-01/026. The NaOH eluent included an organic salt, sodium 4-cyanophenoxide. Detection was by suppressed conductivity. A set of 55 different field samples representing 48 products and previously used by the EPA to assess occurrence of perchlorate in fertilizers (EPA/600/R-01/049) was reanalyzed on the 150 mm column. The 100 mm column was used to further investigate the positive hits. Both columns gave satisfactory performance in fertilizer matrixes, with spike recoveries (±15%), assured reporting levels (0.5–225 µg g−1 except for one at 1000 µg g−1), accuracy (relative error < 30% always and most < 15%), and precision [injection-to-injection reproducibility < 3% relative standard deviation (RSD)] comparable to those reported in other studies. Performance did not vary substantially between column lengths. Lastly, the results of this investigation provided further evidence in support of the conclusions that had been reached previously by the EPA on the occurrence of perchlorate in fertilizers.

Article information

Article type
Paper
Submitted
08 Oct 2001
Accepted
06 Nov 2001
First published
12 Dec 2001

J. Environ. Monit., 2002,4, 149-155

Performance of poly(vinyl alcohol) gel columns on the ion chromatographic determination of perchlorate in fertilizers

B. M. De Borba and E. Todd Urbansky, J. Environ. Monit., 2002, 4, 149 DOI: 10.1039/B109120B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements