Issue 7, 2002

Comparison of extraction procedures for the determination of arsenic and other elements in lobster tissue by inductively coupled plasma mass spectrometry

Abstract

A variety of extraction procedures were evaluated for the extraction of arsenic and other analytes from lobster tissue samples using inductively coupled plasma mass spectrometry (ICP-MS) detection. Soxhlet, room temperature mixing, sonication, microwave assisted, supercritical carbon dioxide and subcritical water extractions were evaluated for a variety of solvent systems and optimum conditions determined using a partially defatted Lobster Hepatopancreas marine certified reference material, TORT-2 (National Research Council of Canada). The solubility trends and solvents into which the analytes extracted gave an indication as to the polar/non-polar nature of the compounds present. Analytes that prefer water are probably more polar or inorganic, while those preferring methanol solutions are less polar or organic in nature. Arsenic, cadmium, cobalt, molybdenum and selenium were probably all present in TORT-2 in both polar inorganic and non-polar organic forms. While TORT-2 may have contained similar amounts of selenium in both forms, the results suggested that more of the arsenic was present as less polar or more organic compounds, and cobalt existed mainly as more polar or inorganic species. Most of the extraction techniques suggested that, although there may be some less polar organic forms present, more of the cadmium was probably present as polar inorganic compounds. Additionally, most techniques indicated that molybdenum was possibly all less polar or more organic in nature. In general, microwave assisted extraction (MAE) yielded comparable or improved recoveries for all of the analytes monitored and usually required less solvent. Additionally, MAE proved to be the mildest, fastest, least complicated and most reproducible extraction technique evaluated. MAE at 75 °C for 2 min exposure time yielded quantitative recovery of arsenic from TORT-2. These conditions were evaluated for lobster tissue samples purchased from a local restaurant. Separate evaluation of the lobster meat and organs resulted in quantitative recoveries of arsenic from both tissue samples. The results indicated that the extraction efficiencies might have some dependence upon the extraction technique, extraction conditions, analyte, solvent, and sample matrix.

Article information

Article type
Paper
Submitted
20 Nov 2001
Accepted
25 Apr 2002
First published
23 May 2002

Analyst, 2002,127, 921-929

Comparison of extraction procedures for the determination of arsenic and other elements in lobster tissue by inductively coupled plasma mass spectrometry

J. A. Brisbin and J. A. Caruso, Analyst, 2002, 127, 921 DOI: 10.1039/B110566C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements