Abstract
Personal exposures and microenvironment concentrations of 30 target VOCs were measured for 401 participants living in five European cities as a part of the EXPOLIS (Air Pollution Exposure Distributions within Adult Urban Populations in Europe) study. Measurements in Basel used an active charcoal (Carbotech) adsorbent as opposed to the Tenax TA used in the other study centres. In addition, within each centre, personal and microenvironment VOC sampling required different sampling pumps and, because of different sampling durations, different sampling flow rates. Thus, careful testing of the sampling and analysis procedures was required to ensure accuracy and comparability of collected data. Monitor comparison tests using Tenax TA showed a mean VOC concentration ratio of 0.95 between the personal and microenvironment monitors. The LODs for the target VOCs using Tenax TA ranged from 0.7 to 5.2 µg m−3. The LODs for the 14 target compounds quantifiable using Carbotech ranged from 0.9 to 3.2 µg m−3. Tenax TA field blanks showed no remarkable contamination with the target VOCs, except