Direct simultaneous analysis of plasma samples for a drug discovery compound and its hydroxyl metabolite using mixed-function column liquid chromatography-tandem mass spectrometry

Abstract

A polymer-coated mixed-function (PCMF) column was evaluated for direct plasma injection for the simultaneous determination of a drug candidate and its hydroxyl metabolite by high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS-MS) in support of pharmacokinetic studies. Each diluted monkey plasma sample containing internal standard was directly injected on to the PCMF column for sample clean-up, enrichment and chromatographic separation. The proteins and macromolecules were first eluted from the column while the drug molecules were retained on the bonded hydrophobic phase. The analytes retained on the column were then eluted with a strong mobile phase using a gradient separation technique at a constant flow rate of 1.0 ml min−1. When not diverted, the column effluent was connected either to the atmospheric pressure chemical ionization (APCI) source or the electrospray ionization (ESI) source as part of the mass spectrometer system used for quantification. The calibration curve was linear over the range 5–2500 ng ml−1 for both analytes. The retention times for the analytes and the internal standard were both consistent and no column deterioration was observed for at least 500 injections. The recovery through the column and reproducibility of the dosed compound and its hydroxyl metabolite in monkey plasma samples were >90% (RSD <6%). The total analysis time was <8 min per sample. The analytical results obtained by the proposed direct plasma injection method were in good agreement with those obtained by the conventional LC-MS-MS method.

Article information

Article type
Paper
Submitted
13 Jun 2001
Accepted
07 Sep 2001
First published
01 Nov 2001

Analyst, 2001,126, 2139-2143

Direct simultaneous analysis of plasma samples for a drug discovery compound and its hydroxyl metabolite using mixed-function column liquid chromatography-tandem mass spectrometry

Y. Hsieh, J. Brisson, K. Ng, R. E. White and W. A. Korfmacher, Analyst, 2001, 126, 2139 DOI: 10.1039/B105205P

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements